I–CLIP Multiple I–Joist Connector GB Patent: 2411216 Load Data Concentrated Point Load – 1 Pair
TO BE USED WITH 2 PLY JOISTS ONLY
Concentrated Point Load – 2 Pairs
MAX 200MM
MAX 200MM
MAX 75MM
Fixings (3.4 x 35mm)
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Characteristic Capacity (kN)
Header (per anchor)
Supported (per anchor)
Header (per anchor)
Supported (per anchor)
Solid Timber Flange I–Joist
Solid Timber Flange I–Joist
LVL Flange I–Joist
LVL Flange I–Joist
3
3
18.08
14.84
3
3
27.12
22.26
Regular Point Loads – 1 Pair
Regular Point Loads – 2 Pairs
Fixings (3.4 x 35mm)
Fixings (3.4 x 35mm)
Characteristic Capacity (kN)
Characteristic Capacity (kN)
Header (per anchor)
Supported (per anchor)
Header (per anchor)
Supported (per anchor)
Solid Timber Flange I–Joist
Solid Timber Flange I–Joist
LVL Flange I–Joist
LVL Flange I–Joist
3
3
9.04
7.42
3
3
13.56
11.13
Installation Instructions Stage 1
Stage 2
Stage 3
Lay I–Joist flat and mark location of I–Clips, press clips into position on top face of I–Joist.
Position second ply of multiple joist on top of I–Clips and tap together with a hammer to ensure a tight fit.
Fix I–Clips to top and bottom flanges of multiple I–Joist using 6No 3.4 x 35mm square twist nails ensuring that I–Joists are fitted tightly together.
The latest most up to date version will always be online and not in print or in downloaded pdf.
91
Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk
Made with FlippingBook Annual report maker