Cullen Technical Guide 2024

/

I–CLIP Multiple I–Joist Connector GB Patent: 2411216 Load Data Concentrated Point Load – 1 Pair

TO BE USED WITH 2 PLY JOISTS ONLY

Concentrated Point Load – 2 Pairs

MAX 200MM

MAX 200MM

MAX 75MM

Fixings (3.4 x 35mm)

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Characteristic Capacity (kN)

Header (per anchor)

Supported (per anchor)

Header (per anchor)

Supported (per anchor)

Solid Timber Flange I–Joist

Solid Timber Flange I–Joist

LVL Flange I–Joist

LVL Flange I–Joist

3

3

18.08

14.84

3

3

27.12

22.26

Regular Point Loads – 1 Pair

Regular Point Loads – 2 Pairs

Fixings (3.4 x 35mm)

Fixings (3.4 x 35mm)

Characteristic Capacity (kN)

Characteristic Capacity (kN)

Header (per anchor)

Supported (per anchor)

Header (per anchor)

Supported (per anchor)

Solid Timber Flange I–Joist

Solid Timber Flange I–Joist

LVL Flange I–Joist

LVL Flange I–Joist

3

3

9.04

7.42

3

3

13.56

11.13

Installation Instructions Stage 1

Stage 2

Stage 3

Lay I–Joist flat and mark location of I–Clips, press clips into position on top face of I–Joist.

Position second ply of multiple joist on top of I–Clips and tap together with a hammer to ensure a tight fit.

Fix I–Clips to top and bottom flanges of multiple I–Joist using 6No 3.4 x 35mm square twist nails ensuring that I–Joists are fitted tightly together.

The latest most up to date version will always be online and not in print or in downloaded pdf.

91

Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk

Made with FlippingBook Annual report maker