Multiple Connections PSTS

Connecting Multiple Glulam & Solid Timber Members With PSTS 8mm Ø

Min 100mm end distance parallel to grain

Min 45mm edge distance perpendicular to grain

Min 100mm between fixings parallel to grain

Min 60mm between fixings perpendicular to grain

Pointside member

Headside member

The figures in table 1 & table 2 assume: 1. The load may be acting parallel or perpendicular to the grain.

2. Minimum pointside penetration of 25mm for Glulam members ( Table 1 ). 3. Minimum pointside penetration of 30mm for solid timber members (Table 2 ).

PSTS 8.0mm – Lateral Load–carrying Capacities – Glulam (Table 1)

Long–term permissible lateral load for a single Paslode STS 8.0mm for common combinations of 2 member joints in Glulam (GL28).

Thickness of Headside Member (mm)

Thickness of Pointside Member (mm)

Long–Term Permissible Lateral Load–Carrying Capacity (kN) Per Fixing Safe Working Load

Long–Term Permissible Lateral Load–Carrying Capacity (kN) Per Fixing Characteristic Capacity

Length of Paslode STS 8.0mm

38 45 38 75

38 45 75 75

65 85

0.90 1.21 1.24 1.46

2.18 2.92 2.99 3.51

100 135

PSTS 8.0mm – Lateral Load–carrying Capacities – Solid Timber (Table 2)

Long–term permissible lateral load for a single Paslode STS 8.0mm for common combinations of 2 member joints in solid timber (TR26).

Thickness of Pointside Member (mm)

Long–Term Permissible Lateral Load–Carrying Capacity (kN) Per Fixing Safe Working Load

Long–Term Permissible Lateral Load–Carrying Capacity (kN) Per Fixing Characteristic Capacity

Thickness of Headside Member (mm)

Length of Paslode STS 8.0mm

35 45 47 75

35 45 47 75

65 85 85

0.86 1.13 1.12 1.38

2.07 2.72 2.69 3.32

135