AUTOMOTIVE A/C Service & Repair 8
U.V. LEAK DETECTION — BASIC STEPS
6 Step Fluorescent Leak Detection System Is Simple ...
1
Pour dye into system or inject it using the appropriate dye injector for A/C systems. Use proper dosage.
2
Operate system to allow thorough circulation and mixing of dye with host fluid. Road testing is recommended.
3
Locate leaks using U.V. Light and Dye-enhancing Safety Glasses.
+
4
Fix the leak.
8
5
Clean the area of leak repair with Fluorescent Dye Cleaner.
+
6
Repeat steps 2 & 3 to verify that leak is fixed.