Intelect Transport ® 2 RESTORE MOTION
INTELECT TRANSPORT ® 2 THE SMART CHOICE
The Intelect Transport 2 line of electrotherapy products provides the reliability and value that only a Chattanooga product can offer. The lightweight, durable design and battery powered option provide the versatility needed to treat your patients and athletes in any professional environment.
Based on decades of experience from the original Intelect Transport and Intelect Mobile line, Intelect Transport 2 is easy and intuitive to use and includes all of the essential features needed to get your patients moving.
KEY BENEFITS
BETTER TREATMENT OUTCOME Improved ultrasound coupling detection and monitoring ensures the patient is receiving the intended energy for his treatment.
QUICK TREATMENT SETUP AND CUSTOMIZATION High resolution color screen with clear, intuitive menus provide real time information on treatment progress. Device memory allows the end user to save up to 15 custom protocols for future use.
IMPROVED PORTABILITY AND VERSATILITY Ergonomically designed device handle, lightweight design and optional long lasting battery makes it easy to treat patients wherever is required within the facility.
REDUCED COMPLEXITY - DEVICE SETUP
Optional cart with large storage drawers ensuring all accessories are conveniently located close to the device. Magnetic fixation of the device to the cart allows for secure attachment and detachment without the need for any tools.
TENS: • Symptomatic relief of acute and chronic pain associated with musculoskeletal conditions 1 • Management and alleviation of post-operative pain 1 NMES: • Skeletal muscle deficit disorders resulting in benefits such as: • Muscle re-education 2 • Maintaining/increasing range of motion 2 ELECTROTHERAPY INDICATIONS
ULTRASOUND INDICATIONS
Ultrasound: • Musculoskeletal conditions; facilitating pain relief to the affected area 3,4
CLINICAL INFORMATION 1. Bilgili A, Çakır T, Doğan ŞK, Erçalık T, Filiz MB, Toraman F. The effectiveness of transcutaneous electrical nerve stimulation in the management of patients with complex regional pain syndrome: A randomized, double-blinded, placebo-controlled prospective study. J Back Musculoskelet Rehabil. 2016 Nov 21;29(4):661-671. doi: 10.3233/BMR-160667. PMID: 26922847. 2. Yoshida Y, Ikuno K, Shomoto K. Comparison of the Effect of Sensory-Level and Conventional Motor-Level Neuromuscular Electrical Stimulations on Quadriceps Strength After Total Knee Arthroplasty: A Prospective Randomized Single-Blind Trial. Arch Phys Med Rehabil. 2017 Dec;98(12):2364-2370. doi: 10.1016/j. apmr.2017.05.005. Epub 2017 Jun 10. PMID: 28610968.
4. Ekici Ö, Dündar Ü, Gökay GD, Büyükbosna M. Evaluation of the efficiency of different
treatment modalities in individuals with painful temporomandibular joint disc displacement with reduction: a randomised controlled clinical trial. Br J Oral Maxillofac Surg. 2021 Aug 26:S0266- 4356(21)00305-3. doi: 10.1016/j.bjoms.2021.08.001. Epub ahead of print. PMID: 34756640. 5. Waschl S, Morrissey MC, Rugelj D. The efficacy of ultrasound-facilitated electrical stimulation as an adjunct to exercise in treating chronic neck and shoulder pain. Journal of musculoskeletal pain, 2014, 22(1), 78‐88 | added to CENTRAL: 30 June 2014 | 2014 Issue 6
3. Catalbas et al Ultrasonographic imaging of the effects of continuous, pulsed or sham ultrasound treatments on carpal tunnel syndrome: A randomized controlled study J Back Musculoskelet Rehabil. 2018;31(5):981-989.
INTELECT TRANSPORT ® 2 COMBO
SPECIFICATION The Intelect Transport 2 COMBO is a two-channel electrotherapy, ultrasound therapy and combo system used with or without an optional cart. For electrotherapy treatments, 14 waveforms are included. ELECTRO STIMULATION SPECIFICATION Unless otherwise specified, electrotherapy controls accuracy is ± 20% Load impedance: 500-1000 Ohm CC = constant current, effect of load impedance on voltage CV = constant voltage, effect of load impedance on current
DID YOU KNOW?
The combined use of Ultrasound and Electrotherapy can reduce the pain intensity by 64% on a VAS scale in patients with chronic neck and shoulder pain. 5
WAVEFORMS
INTERFERENTIAL 4 POLE
INTERFERENTIAL 2 POLE
HIGH VOLTAGE PULSED CURRENT
VMS™
GALVANIC CONTINUOUS
MICROCURRENT
TENS - ASYMM BIPH
TENS - SYMM BIPH
MONOPHASIC TRIANGULAR PULSED
MONOPHASIC RECTANGULAR PULSED
GALVANIC INTERRUPTED
TRABERT
RUSSIAN
DIADYNAMIC
ORDERING INFORMATION
STANDARD ACCESSORIES IN THE KIT
PART NUMBER
DESCRIPTION
PART NUMBER
DESCRIPTION
Intelect Transport 2 Combo English/ French/Spanish
47383
5cm2 Ultrasound Applicator
4778
International Accessory Kit: Stim CH1/2 Leadwire Silicon/Carbon Electrode 6x8 cm Black Sponge Pocket 9x10.5cm Nylatex Wrap 2-1/2x24 Sewn Dura-Stick+ 5 cm Round Electrodes Mains Power Cord EU for 4778, 4778-L1 and 4778-L 2 Mains Power Cord US and EU for 4778-L3*
Intelect Transport 2 Combo English/German/Polish/ Greek/Italian/Dutch/Brazilian Portuguese Intelect Transport 2 Combo English/Czech/Slovak/ Turkish/Russian/Ukraine/Portugal Portuguese Intelect Transport 2 Combo English/Korean/Chinese/ Hungarian/Romanian/Croatian/Japanese
4778-L1
48100
4778-L2
4778-L3
* for others Power Cords see back page
INTELECT TRANSPORT ® 2 ULTRASOUND
SPECIFICATION The Intelect Transport 2 ULTRASOUND is an ultrasound therapy system used with or without an optional cart. Ultrasound frequencies of 1 or 3.3 MHz are available with pulsed or continuous duty cycles. The device comes standard with a 5cm 2 ultrasound applicator with additional sizes available. ULTRASOUND SPECIFICATION Frequency: 1MHz; 3.3 MHz Duty Cycles: 10%, 20%. 50%, Continuous Pulse Repetition Rate: 100Hz Pulse duration: 1 - 5 ms - Max (ON): 5 ms - Min (OFF): 5 ms
DID YOU KNOW?
Coupling detection settings give the option to alert the clinician when the applicator has become decoupled from the patient by an audible beep and stopping the treatment timer.
OUTPUT POWER
5cm 2
10cm 2
2cm 2
5cm 2
10cm 2
2cm 2
ULTRASOUND APPLICATOR FREQUENCY
ULTRASOUND APPLICATOR FREQUENCY MAX OUTPUT POWER IN PULSED MODE MAX INTENSITY IN CONTINUOUS MODE
1MHz 3.3MHz 1MHz 3.3MHz 1MHz 3.3MHz
1MHz 3.3MHz 1MHz 3.3MHz 1MHz 3.3MHz
EFFECTIVE RADIATING AREA ERA INTL (CM 2 )
4.5W 4.5W 9W 9W 17.4W 13.9W
1.5
1.5 3.0 3.0 5.8 5.8
2W/ cm2
2W/ cm2
2W/ cm2
2W/ cm2
2.2W/ cm2
1.2W/ cm2
MAX OUTPUT POWER IN CONTINUOUS MODE
3W 3W 6W 6W 12.7W 6.9W
MAX INTENSITY IN PULSED MODE
3W/ cm2
3W/ cm2
3W/ cm2
3W/ cm2
3W/ cm2
3W/ cm2
ORDERING INFORMATION
STANDARD ACCESSORIES IN THE KIT
PART NUMBER
DESCRIPTION
PART NUMBER
DESCRIPTION
Intelect Transport 2 Ultrasound English/ French/Spanish
47383
5cm2 Ultrasound Applicator Mains Power Cord EU for 4776, 4776-L1 and 4776-L 2 Mains Power Cord US and EU for 4776-L3*
4776
Intelect Transport 2 Ultrasound English/German/ Polish/Greek/Italian/Dutch/Brazilian Portuguese Intelect Transport 2 Ultrasound English/Czech/Slovak/ Turkish/Russian/Ukraine/Portugal Portuguese Intelect Transport 2 Ultrasound English/Korean/ Chinese/Hungarian/Romanian/Croatian/Japanese
4776-L1
4776-L2
4776-L3
* for others Power Cords see back page
INTELECT TRANSPORT 2 ORDERING INFORMATION
POWER CORD ACCESSORIES
Not part of the initial kit but mandatory, to be ordered separately.
14815
Mains Power Cord UK
14816
Mains Power Cord India
14819
Mains Power Cord Australia
OPTIONAL ACCESSORIES
47382
2cm 2 Ultrasound Applicator
5cm 2 Ultrasound Applicator
47383
10cm 2 Ultrasound Applicator
47384
15-1136
Electrotherapy Cart
14-1086
Battery
42192
Dura-Stick+ 5cm Round Electrodes (10/Pk)
79970
Sponge Pocket 9x10.5cm (4/Pk)
10648
Nylatex Wrap (2/Pk)
70010
Stim CH 1/2 Leadwire Kit
79967
Silicon/Carbon Electrode 6x8 cm Black
14820
Mains Power Cord EU
14679
Mains Power Cord US
Enovis™ - DJO France S.A.S., C.E.F., 3 rue de Bethar, 64990 Mouguerre, FRANCE chattanoogarehab.com
Individual results may vary. Neither Enovis, DJO, LLC or any of their subsidiaries dispense medical advice. The contents of this document do not constitute medical, legal, or any other type of professional advice. Rather, please consult your healthcare professional for information on the courses of treatment, if any, which may be appropriate for you. MKT00-12609 Rev B Copyright © 2024 DJO, LLC, a subsidiary of Enovis Corporation
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8Made with FlippingBook - PDF hosting