MD_909530_HVAC Catalog

Condensers

Rooftop condensers

Product overview and technical data

Model

Part Number

Capacity

Dimensions L x W x H

Specifications

Power consumption at 12 V (A)

Weight Voltage

Capri*

62U00025456

35,800 BTU/h (10.5 kW)

32.1 x 23.6 x 5.9 in (815 x 600 x 150 mm)

HTC condenser, fin pitch .1 in (2.5 mm) , Integrated Receiver Dryer

18 A 26.5 lbs (12 kg)

12 V

Valencia*

62U00025437

42,650 BTU/h (12.5 kW)

37.6 x 23.6 x 5.9 in (955 x 600 x 150 mm)

HTC condenser, Integrated Receiver Dryer

27 A

31 lbs (14 kg)

12 V

* NOTE: This unit does not come with a pressure switch.

Product overview and technical data Under chassis condensers

Model

Part Number

Capacity

Dimensions L x W x H

Specifications

Power consumption at 12 V (A)

Weight Voltage

HTC Condenser Units

62U00025427

17,000 BTU/h (5 kW) 24,000 BTU/h (7 kW) 22,200 BTU/h (6,5 kW) 41,000 BTU/h (12 kW) 47,800 BTU/h (14 kW) 41,000 BTU/h (12 kW)

23.9 x 4.3 x 13.8 in (606 x 110 x 350 mm)

fin pitch 0.14 in (3.5 mm) fin pitch 0.1 in (2.5 mm) fin pitch 0.1 in (2.5 mm) fin pitch 0.14 in (3.5 mm) fin pitch 0.1 in (2.5 mm) fin pitch 0.1 in (2.5 mm)

18 A 9.9 lbs (4.5 kg)

12 V

62U00025460

62U00025453

18.9 x 4.3 13.8 in (480 x 110 x 350 mm)

12 A 8.2 lbs (3.7 kg)

62U00025426

28.5 x 4.1 x 17.7 in (725 x 105 x 450 mm)

27 A 13.2 lbs (6 kg)

62U00025459

62U00025472

23.9 x 6.3 x 13.8 in (606 x 160 x 350 mm)

32 A 16.5 lbs (7.5 kg)

31