Fluke Australia 2021 Test Tools Catalogue

Fluke 771, 772 and 773 mA Process Clamp Meters

Recommended Accessories

Don’t break the loop on 4-20 mA signal measurements and save time with the Fluke 771, 772 and 773 Milliamp Process Clamp Meters Three year warranty, (one year provided on mA clamp assembly and cable) Use the Fluke 772 and 773 to: • Source 4-20 mA signals for testing control system I/O or I/Ps • Simulate 4-20 mA signals for testing control system I/O • Measure 4-20 mA signals with in-circuit measurement • Power a transmitter with the 24 V loop power supply • Automatically ramp and step change the 4-20 mA output for remote testing Use the Fluke 773 to: • Measure DC voltage to verify 24 V power supplies or voltage I/O signals • Source DC voltage to test voltage input devices • Scaled mA output signal enables a logging DMM (289) to record 4-20 mA signal without breaking the loop • mA in/out: simultaneously source a mA signal while measuring a mA signal with the clamp

TL220 SureGrip™ Industrial Test Lead Set See page 145

C550 Tool Bag See page 154

Fluke 771, 772 and 773 mA Process Clamp Meters pay for themselves • The more you use them the more money you save • Measuring 4-20 mA signals (five) times without operator intervention can pay for the 771 • Saving a trip back to shop to get a loop calibrator can pay for the price difference of the 772 • Saving a trip back to the shop for a voltage test source can pay for the price difference of the 773

Fluke 773

Fluke 772

Fluke 771

mA measure In circuit

mA measure w/jaw

Loop power 24 V

DCV source 0-10 V

DCV measure 0-30 V

Scaled mA output to mA input

mA source

mA sim

mA in/ out

● ● ●

— — — —

— —

— —

— —

— —

771 772 773

● ●

● ●

● ●

● ●

Resolution and range

Specifications Function

Accuracy

Notes

0 to 20 99 mA

0 2% + 5 counts Measured by clamp

771, 772, 773

mA measurement

21 0 mA to 100 0 mA 1% + 5 counts

Measured in series with test jacks Maximum mA drive: 24 mA into 1,000 ohms

772 and 773

mA measurement

0 to 24 00 mA

0 2% + 2 counts

772 and 773

mA source

0 to 24 00 mA

0 2% + 2 counts

772 and 773

mA simulate

0 to 24 00 mA

0 2% + 2 counts Maximum voltage 50 V DC 0 2% + 2 counts 2 mA maximum drive current

Included Accessories Fluke 771: Soft Carrying Case, User Manual Fluke 772/773: Four AA Alkaline Batteries (installed), Soft Carrying Case, TL75 Test Leads, AC 72 Detachable Clip, TL940 Mini-hook Test Leads, Instruction Sheet, Hanging Tool with Hook and Loop Strap Ordering Information FLUKE-771 Milliamp Process Clamp Meter FLUKE-772 Milliamp Process Clamp Meter FLUKE-773 Milliamp Process Clamp Meter

773

Voltage source

0 to 10 00 V DC

773

Voltage measure 0 to 30 00 V DC

0 2% + 2 counts —

771

772

773

Battery

Two 1 5 V, Alkaline, IEC LR6

Four 1 5 V, Alkaline, IEC LR6

Working hours Size (H×W×L)

40 hours typical

12 hours @ 12 mA source into 500 ohms

59 mm × 38 mm × 212 mm

43 7 mm × 70 mm × 246 2 mm

Weight

260 g

410 g

Operating temperature

-10°C to 50ºC

IP rating

IP 40

C ontact your local distributor for price and availability. fluke.co/wtb

104

Process Calibration Tools

Loop Calibration

Made with FlippingBook Learn more on our blog