Fluke Australia 2021 Test Tools Catalogue

Fluke 730G Precision Pressure Test Gauges

Pressure 3 psi, 210 mbar 20 6 kPa 5 psi 350 mbar 34 4 kPa 60 psi 4 bar 413 6 kPa 120 psi 8 bar 827 3 kPa 400 psi 26 bar 2 757 MPa 1200 psi 80 bar 8 273 MPa 2000 psi 138 bar 13 789 MPa 4000 psi 266 bar 27 579 MPa 8000 psi 550 bar 55 158 MPa 10000 psi 690 bar 68 947 MPa 10000 psi 690 bar 68 947 MPa 15000 psi 1035 bar 103 421 MPa

Model

Range

Resolution 0 001 inH2O 0 001 mbar 0 0001 kPa 0 0001 psi 0 001 mbar 0 0001 kPa 0 001 psi 0 0001 bar 0 01 kPa 0 001 psi 0 0001 bar 0 01 kPa 0 01 psi 0 0001 bar 0 01 kPa 0 01 psi 0 001 bar 0 1 kPa 0 01 psi 0 001 bar 0 1 kPa 0 1 psi 0 001 bar 0 1 kPa 0 1 psi 0 01 bar 1 kPa 0 1 psi 0 01 bar 1 kPa 0 1 psi 0 01 bar 1 kPa 1 psi 0 01 bar 1 kPa 0 001 psi 0 0001 bar 0 01 kPa 0 001 psi 0 0001 bar 0 01 kPa 0 01 psi 0 0001 bar 0 01 kPa 0 01 psi 0 001 bar 0 01 kPa 0 001 psi 0 0001 bar 0 0001 kPa 0 001 psi 0 0001 bar 0 01 kPa 0 01 psi 0 0001 bar 0 01 kPa 0 01 psi 0 001 bar 0 1 kPa

Accuracy 1

-10 to +10 inH2O -20 to 20 mbar -2 49 to 2 49 kPa -1 to +1 psi -70 to 70 mbar -6 89 to 6 89 kPa -14 to 15 psi -0 97 to 1 bar -97 to 103 kPa -14 to 30 psi -0 97 to 2 bar -97 to 206 kPa -12 to 100 psi -0 83 to 6 9 bar -83 to 690 kPa -12 to 300 psi -0 83 to 20 bar -83 to 2 MPa -12 to 500 psi -0 83 to 34 bar -83 to 3 4 MPa -14 to 1000 psi -0 97 to 69 bar -97 to 6 9 MPa -14 to 2000 psi -0 97 to 140 bar -97 to 14 MPa -14 to 3000 psi -0 97 to 200 bar -97 to 20 MPa -14 to 5000 psi -0 97 to 340 bar -97 to 34 MPa -14 to 10000 psi -0 97 to 690 bar -97 to 69 MPa

730G01

Positive pressure, ± 0 2% of range 2 Vacuum, ± 0 2% of range 2

730G02

Recommended Kits

Bundle & Save

730G04

730G05

Fluke-700PTPK Pneumatic Test Kit

730G06

730G27

730G07

Positive pressure, ±0 05% of range Vacuum, ±0 1% of range

730G08

Fluke-700HTPK Hydraulic Test Kit

730G10

For more details see page 164

730G29

Included Accessories 730G: Rechargeable Li-ion Battery Pack, AC Power Battery Charger, ¼” FNPT to ¼” MBSP Fitting, ¼” FNPT to M20 Male Fitting, Test Lead Set, Alligator Clips (black and red), 1 metre USB Cable Ordering Information Please refer to the table on the left for Fluke 730G Models FLUKE- 730PCSWCN Pressure Calibration Software FLUKE- 700HTPK Hydraulic Test Pump Kit, 0 to 10000 psi/ 690 bar FLUKE- 700PTPK Pneumatic Test Pump Kit, 0 to 600 psi/40 bar

730G30

730G31

60 psi 4 bar 413 6 kPa 120 psi 8 bar 827 3 kPa 400 psi 27 bar 2 757 MPa 1200 psi 80 bar 8 273 MPa 45 psi 3 bar 310 2 kPa 90 psi 6 bar 620 5 kPa 1000 psi 69 bar 6 894 MPa

0 to 15 psia 0 to 1 bar 0 to 100 kPa absolute 0 to 30 psia 0 to 2 bar 0 to 200 kPa absolute 0 to 100 psia 0 to 6 9 bar 0 to 690 kPa absolute 0 to 300 psia 0 to 20 bar 0 to 2 MPa absolute

730GA4

730GA5

± 0 05% of range 4

730GA6

730GA27

-14 to 15 psi -0 97 to 1 bar -97 to 100 kPa -14 to 30 psi -0 97 to 2 bar -97 to 200 kPa

730RG04

730RG05

-12 to 100 psi -0 83 to 6 9 bar -83 to 690 kPa –12 psi to 300 psi -0 83 to 20 bar –80 kPa to 2 MPa –12 psi to 500 psi -0 83 to 34 bar –80 kPa to 3 5 MPa -14 to 1000 psi -0 97 to 69 bar -97 to 6 9 MPa -14 to 3000 psi -0 97 to 200 bar -97 to 20 MPa -14 to 5000 psi -0 97 to 340 bar -97 to 34 MPa -14 to 10000 psi -0 97 to 690 bar -97 to 69 MPa

730RG06

2000 psi 138 bar 14 MPa

FLK- 730LTP/40K

Low Pressure Test Pump, -40 to 40 kPa Low Pressure Test Pump, -95 to 600 kPa Pneumatic Test Pump, -0 095 to 10 MPa Hydraulic Test Pump, 0 to 70 MPa

730RG27

Positive pressure, ± 0 02% of range 3 Vacuum, ± 0 05% of range 3

0 01 psi 0 001 bar 0 1 kPa 0 1 psi 0 001 bar 0 1 kPa 0 1 psi 0 01 bar 1 kPa 0 1 psi 0 01 bar 1 kPa 0 1 psi 0 01 bar 1 kPa

2000 psi 138 bar 13 789 MPa 10000 psi 690 bar 68 947 MPa 10000 psi 690 bar 68 947 MPa 10000 psi 690 bar 68 947 MPa 15000 psi 1035 bar 103 421 MPa

730RG07

FLK- 730LTP/600K

730RG08

FLK- 730PTP/10M

730RG29

730RG30

FLK- 730HTP/70M

730RG31

FLK-730PFK Pressure Fitting Kit FLK-730GLSF Gas and Liquid Separation Filter FLK-730ILF In-line Liquid Filter

Pressure Specifications: 0 02% of full scale (730RG), 0 05% of full scale (730G) Current Specifications: 0 01% of reading 1 Accuracy specifications above have considered the effects of linearity, repeatability, resolution, reference accuracy, 1-year stability, and temperature effect 2 For 730G01/730G02, accuracy is ± 0 3% of full scale @ 0°C to 15°C and 35°C to 50°C 3 For all 730RG model, add 0 003% FS/°C @ 0°C to 18°C and 28°C to 50°C 4 For 730GA4, add 0 006% FS/°C @ -10°C to 15°C and 35°C to 55°C; for all other 730GA model, add 0 003% FS/°C @ -10°C to 15°C and 35°C to 55°C Media compatibility: • 10 inH 2 0, 1, 15, 30 psi: any clean dry non-corrosive gas • 100, 300, 500, 1000 psi: any liquids or gases compatible with 316 stainless steel and above 1000 psi: any non- flammable, non-toxic, non-explosive, non-oxidising liquid or gas compatible with 316 stainless steel • 730G01, 730G02, 730G04, 730G05, 730RG04, 730RG05: any clean dry non-corrosive gas • Above 100 psi: any liquids or gases compatible with 316 stainless steel

C ontact your local distributor for price and availability. fluke.co/wtb

fluke.co/calibration

Process Calibration Tools

125

Made with FlippingBook Learn more on our blog