AC/DC CURRENT CLAMPS
AC/DC Current Clamp Specifications
80i-110s
i410
i1010
i30
i30s
i310s
DC range AC range
0 1 A to 100 A 0 1 A to 70 A
1 A to 400 A 1 A to 400 A
1 A to 1000 A 1 A to 600 A
30 mA to 30 A
30 mA to 30 A
0 1 A to 450 A
30 mA to 20 A RMS 30 mA to 20 A RSM 0 1 A to 300 A
30 A range: 1% + 50 mA 300 A range: 1% + 300 mA
0 1 A to 10 A; AC to 1 kHz: ± 3% + 50 mA; up to 100 A add 15%; up to 20 kHz add 12%
3 5% + 0 5 A for DC or AC (45 to 400 Hz)
2% + 0 5 A for DC or AC (45 to 400 Hz)
± 1% of reading, ± 2 mA
± 1% of reading, ± 2 mA
Accuracy
Bandwidth (-3 dB)
100 kHZ
3 kHz
10 kHz
dc to 20 kHz (-0 5 dB) dc to 100 kHz (-0 5 dB)
dc to 20 kHz
Zero error adjustment
•
•
•
•
•
•
Maximum conductor diameter Maximum conductor size
11 8 mm
30 mm
30 mm
19 mm
19 mm
19 mm
1× 400 mm² or 2× 240 mm²
1× 400 mm² or 2× 240 mm²
35 mm
120 mm²
120 mm²
120 mm²
2
Output levels
10 mV/A, 100 mV/A
1 mV/A
1 mV/A
100 mV/A
100 mV/A
1 mV/A, 10 mV/A
2 metres with BNC termination and a BNC to safety shrouded banana adapter
1 2 metre with shrouded banana plugs
1 2 metre with shrouded banana plugs
1 5 metre with shrouded dual banana plugs
1 6 metre with BNC termination
2 metres with BNC termination
Output cable
Battery life Warranty
40 hours One-year
60 hours One-year
60 hours One-year
30 hours One-year
30 hours One-year
30 hours One-year
CAT II 600 V; CAT III 300 V
Safety
CAT III 600 V
CAT III 600 V
CAT III 300 V
CAT III 300 V
CAT III 300 V
AC/DC Current Clamp Selection Guide
80i-110s
i410
i1010
i30
i30s
i310s
114/115/ 116/117
0 1 A to 100 A DC/ 0 1 A to 70 A AC* 0 1 A to 100 A DC/ 0 1 A to 70 A AC* 0 1 A to 100 A DC/ 0 1 A to 70 A AC* 0 1 A to 100 A DC/ 0 2 A to 70 A AC* 0 1 A to 100 A DC/ 0 1 A to 70 A AC*
1 4 A to 400 A DC/ 6 A to 400 A AC 1 4 A to 400 A DC/ 6 A to 400 A AC 1 A to 400 A DC/ 1 A to 400 A AC 1 A to 400 A DC/ 6 A to 400 A AC 1 A to 400 A DC/ 5 A to 400 A AC 1 6 A to 400 A DC/ 30 A to 400 A AC 1 2 A to 400 A DC/ 30 A to 400 A AC 1 A to 400 A DC/ 1 A to 400 A AC 1 A to 400 A DC/ 20 A to 400 A AC 1 A to 400 A DC/ 1 A to 400 A AC 1 A to 400 A DC/ 25 A to 400 A AC** 1 A to 400 A DC/ 5 A to 400 A AC** 1 A to 400 A DC/ 2 A to 400 A AC 1 A to 400 A DC/ 1 A to 400 A AC 4 A to 400 A DC, no AC 4 A to 400 A DC, no AC 1 A to 400 A DC/ 20 A to 400 A AC
1 4 A to 1000 A DC/ 6 A to 600 A AC 1 4 A to 1000 A DC/ 6 A to 600 A AC 1 A to 1000 A DC/ 1 A to 600 A AC 1 A to 1000 A DC/ 6 A to 600 A AC 1 A to 1000 A DC/ 5 A to 600 A AC 1 6 A to 1000 A DC/ 30 A to 600 A AC 1 2 A to 1000 A DC/ 30 A to 600 A AC 1 A to 1000 A DC/ 1 A to 600 A AC 1 A to 1000 A DC/ 20 A to 600 A AC 1 A to 1000 A DC/ 1 A to 600 A AC 1 A to 1000 A DC/ 25 A to 600 A AC** 1 A to 1000 A DC/ 5 A to 600 A AC** 1 A to 1000 A DC/ 2 A to 600 A AC 1 A to 1000 A DC/ 1 A to 600 A AC 4 A to 1000 A DC, No AC 4 A to 1000 A DC, No AC 1 A to 1000 A DC/ 20 A to 600 A AC
30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 40 mA to 20 A AC 30 mA to 30 A DC/ 300 mA to 20 A AC 30 mA to 30 A DC/ 300 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 200 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 50 mA to 20 A AC** 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 40 mA to 30 A DC, no AC 40 mA to 30 A DC, no AC 30 mA to 30 A DC/ 200 mA to 20 A AC
30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 60 mA to 20 A AC 30 mA to 30 A DC/ 40 mA to 20 A AC 30 mA to 30 A DC/ 300 mA to 20 A AC 30 mA to 30 A DC/ 300 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 200 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 250 mA to 20 A AC 30 mA to 30 A DC/ 50 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 30 mA to 30 A DC/ 30 mA to 20 A AC 40 mA to 30 A DC, no AC 40 mA to 30 A DC, no AC 3 mA to 30 A DC/ 200 mA to 20 A AC
0 1 A to 450 A DC/ 0 6 A to 300 A AC 0 1 A to 450 A DC/ 0 6 A to 300 A AC 0 1 A to 450 A DC/ 0 1 A to 300 A AC 0 1 A to 450 A DC/ 2 A to 300 A AC 0 1 A to 450 A DC/ 0 4 A to 300 A AC 0 1 A to 450 A DC/ 3 A to 300 A AC 0 1 A to 450 A DC/ 3 A to 300 A AC 0 1 A to 450 A DC/ 0 1 A to 300 A AC 0 1 A to 450 A DC/ 2 A to 300 A AC 0 1 A to 450 A DC/ 0 1 A to 300 A AC 0 1 A to 450 A DC/ 2 5 A to 300 A AC 0 1 A to 450 A DC/ 0 5 A to 300 A AC 0 1 A to 450 A DC/ 0 2 A to 300 A AC 0 1 A to 450 A DC/ 0 1 A to 300 A AC 0 4 A to 450 A DC, no AC 0 1 A to 450 A DC, no AC 0 1 A to 450 A DC/ 2 A to 300 A AC
233
27II
28II
77-IV
175/177/179 0 11 A to 100 A DC/ 0 3 A to 70 A AC*
0 1 A to 100 A DC/ 0 3 A to 70 A AC* 0 1 A to 100 A DC/ 0 1 A to 70 A AC* 0 1 A to 100 A DC/ 0 2 A to 70 A AC* 0 1 A to 100 A DC/ 0 1 A to 70 A AC* 0 1 A to 100 A DC/ 0 25 A to 70 A AC 0 1 A to 100 A DC/ 0 1 A to 70 A AC 0 1 A to 100 A DC/ 0 1 A to 70 A AC*
1577/1587 FC
83V/88V
87V
287/289
123/124
190 Series II
8808A
8845A/8846A 0 1 A to 100 A DC/ 0 1 A to 70 A AC*
0 1 A to 100 A DC, no AC* 0 1 A to 100 A DC, no AC* 0 1 A to 100 A DC/ 0 2 A to 70 A AC*
705/707
715
787/789
* Requires PM9081 Adapter ** Requires PM9082/001 Adapter