Fluke Australia 2021 Test Tools Catalogue

NEW

Fluke T6 Series Electrical Testers with FieldSense™

Measure voltage without test leads Measure voltage up to 1000 V AC through the open fork, without test lead contact to live voltage + Without opening covers or removing wire nuts; on wires up to 4/0 (120 mm 2 ), carrying as much as 200 A It will change your job • FieldSense™ technology for AC voltage, current and frequency measurement without making electrical contact to live voltage + • Simultaneous voltage and current display (T6-1000 & T6-1000 PRO) – shows all power supply measurements at a glance for efficient troubleshooting • T6-1000 PRO features Visual Continuity™ – the screen acutomatically lights up green for continuity, perfect when it’s too loud to hear the beeper • Works with wire up to AWG 4/0 (17 8 mm jaw opening) • HOLD button temporarily freezes the reading for easy viewing • Easy to read display with backlight • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation • Two year warranty + Voltage measurement requires capacitive path to ground, provided through user in most applications Ground connection via test lead may be required in some situations The Full Package The Fluke T6-1000 PRO Electrical Tester comes with a belt holster and black alligator clip as standard Measure wires up to AWG 4/0 (120 mm 2 ), carrying as much as 200 A and 1000 V AC, even with gloves on

Recommended Accessories

HT6 Belt Holster See page 155

T5-RLS T5 Replacement Test Leads

PRV240FS Proving Unit See page 24

AC285 SureGrip Alligator Clips See page 142

Recommended Kits Bundle & Save

Fluke T6-600

Fluke T6-1000

Fluke T6-1000 PRO NEW

True RMS

Fluke T6-600/62MAX+/1AC Combo Kit

Fluke T6-1000/ H-T6 Holster/ 1AC-A1 Combo Kit

T6-1000/ T6-1000 PRO

Specifications

T6-600

Fluke T6-1000/PRV240FS Proving Unit Combo Kit For more details see page 171

1

Function Requires Test Leads

Range

Range

Resolution

Accuracy

FieldSense™ AC voltage FieldSense™ AC current FieldSense™ frequency (Hz)

±(3% + 3 counts) 2 3 45 Hz - 66 Hz ±(3% + 3 counts) 45 Hz - 66 Hz

No

600 V

1000 V

1 V

No

200 0 A

200 0 A

0 1 A

No

45 Hz – 66 Hz

1 Hz

±(1% + 2 counts) 3

Included Accessories Attached Test Leads with removable 4 mm Probe Cap and User Documentation Ordering Information T6-600 Electrical Tester T6-1000 Electrical Tester T6-1000 PRO PRO Electrical Tester T6-600/ 62MAX+/1AC T6-600 Tester, 62MAX+ & 1AC-II Kit T6-HT6-1AC KIT T6-1000 Tester, H-T6 Holster & 1AC Kit T6-1000/ PRV240FS T6-1000 & PRV240FS Proving Unit Kit

±(1 5% + 2 counts) 45 Hz - 66 Hz ±(1% + 2 counts) ±(1% + 2 counts) ±(1% + 2 counts) ±(1% + 2 counts)

Volts AC

Yes

600 V

1000 V

1 V

Volts DC

Yes Yes Yes Yes

600 V

1000 V 2000 Ω

1 V 1 Ω

Resistance

2000 Ω

20 00 kΩ 100 0 kΩ

0 01 kΩ

0 1 kΩ

Safety (measurement category)

1000 V CAT III 600 V CAT IV

600 V CAT III

Accuracy 1 : ± ( [% of reading] + [number of least significant digits] ) Accuracy is specified for 1 year after calibration, at 18°C to 28°C (64°F to 82°F) with relative humidity to 90% AC conversions are ac-coupled, RMS responding Accuracy (2 : Add 3% without an external ground connection External ground connection required for user wearing insulated gloves, standing on an insulated ladder and otherwise insulated from earth ground Accuracy 3 : FieldSense™ specified from 16V to 100% of range

fluke.co/basictesters

Electrical Testers

37

Made with FlippingBook Learn more on our blog