Fluke Australia 2021 Test Tools Catalogue

Fluke 434-II, 435-II and 437-II, Series Three-Phase Power Quality Analysers

Recommended Accessories

The Fluke 434-II, 435-II and 437-II Power Quality Analysers help locate, predict, prevent and troubleshoot power quality problems in three and single-phase power distribution systems Additionally, the Fluke- patented energy loss algorithm, Unified Power Measurement, measures, quantifies and monitises energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system • Patented energy loss management: Classic active and reactive power measurements unbalance and harmonic power and energy are quantified to pinpoint true system energy losses • Realtime PowerWave data capture: Capture fast RMS data, show single cycle RMS value to characterise electrical system dynamics (generator start-ups, UPS switching etc ) • Highest safety rating in the industry: CAT IV 600 V/ CAT III 1000 V rated for use at the service entrance • Automatic transient mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard intervals for 435-II and 437-II • Troubleshoot real-time: Analyse the trends using the cursors and zoom tools—even while background recording continues • Measure all three phases and neutral: With included four iFlex ® flexible current probes • Monitise energy loss caused by power quality issues • Three year warranty

i6000S FLEX AC Current Clamp See page 149

i5SPQ3 5A AC Current Clamps, 3 Pack See page 160

i430-FLEXI-TF-4PK 6000A Fluke 43X Thin Flexi 24inch 4 Pack See page 160

C437-II Water-tight hard case with rollers See page 160

Fluke 437-II

Fluke 435-II

Fluke 434-II

Energy Loss Calculator

Included Accessories TL430 Test Lead and Alligator Clip Set, i430flex-TF-II (60 cm 4 Clamps), BC430 Power Adapter, BP290 Single Capacity Li-ion Battery, International Plug Adapter Set, WC100 Colour Coding Clips and Regional Decals, 8GB SD Card, PowerLog on CD, USB Cable A-B Mini, C1740 Soft Case (434-II, 435-II),

On all inputs

Track harmonics up to the 50th, and measure and record THD

Phasor diagram

C437 Hard Case (437-II) Ordering Information FLUKE- 437-II

434-II

435-II

437-II

IEC 61000-4-30 Class S

IEC 61000-4-30 Class A

IEC 61000-4-30 Class A

Standard compliance

400Hz Three-Phase Power Quality and Energy Analyser 400Hz Three-Phase Power Quality and Energy Analyser (without Clamps) Three-Phase Power Quality and Energy Analyser Three-Phase Power Quality and Energy Analyser (without Clamps) Three-Phase Energy Analyser Three-Phase Energy Analyser (without Clamps)

• • • • • • • •

• • • • • • • • • • • • • •

• • • • • • • • • • • • • • •

Volt Amp Hz

Dips and swells

Harmonics

FLUKE- 437-II/ BASIC

Power and energy Energy loss calculator

Unbalance

FLUKE- 435-II

Monitor Inrush

Event waveform capture

- - - - -

FLUKE- 435-II/ BASIC FLUKE- 434-II FLUKE- 434-II/ BASIC

Flicker

Transients

Mains signaling

Power wave

Power inverter efficiency

400Hz

-

-

C1740 Soft Case

-

C437-II Hard Case with rollers SD card (Max 32 GB)

-

-

8 GB

8 GB

8 GB

C ontact your local distributor for price and availability. fluke.co/wtb

fluke.co/powerquality

Power Quality

89