2. The screwdriver will automatically reset itself for the next application. 3. With its unique cam-over design, it’s impossible to over-tighten beyond the pre-set load. Battery When a low battery status is detected, the FGA will indicate it by displaying "bAt" on the screen. The battery needs to be replaced.
Note: The FGA doesn't have a battery status icon that displays the battery level status permanently. The low battery indicator will only display once the estimated battery life is <10%
Battery Replacement 1. Use a 1.5mm hexagonal key to loosen the two screws and remove
the battery cover.
2. Remove the battery from the battery holder.
3. Insert a new battery.
Battery (CR1225) for FGA v2
Mountz Item # 982-000025
4. Install a battery cover.
Remove & insert battery
Remove screws
Maintenance Schedule Like an automobile, torque screwdrivers contain moving parts that require periodic servicing and lubrication.
Expected Tool Life With normal use – 1,000,000 operations
Routine Maintenance After 100,000 operations, strip, clean and re-grease the spring, bearings and internal components. Any worn components should be replaced. Note: Any tool that is dismantled during its life must be re-lubricated in accordance with the Mountz recommendations. Do not clean tools by immersing them in a solvent, as this will destroy the internal lubrication and cause the failure of the tool.
SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com
3