HOW TO INSTALL OPEN-JOINT CLADDING TREX TRANSCEND ®
NOTES: » Only Trex Transcend square-edge profiles are approved for use in cladding applications. » Consult local building code officials regarding applicable requirements of cladding applications, including that of proper methods of attachment of cladding framing supports. » Always install wood or steel furring strips over a flat substrate or a suitable cladding substructure. » Ensure that proper gapping requirements are followed as listed within instructions. » Open-joint facades are permitted when following Trex Cladding install instructions.
TOOLS NEEDED
TREX-APPROVED PRODUCT FOR CLADDING APPLICATIONS:
PROFILE
DESCRIPTION
ITEM #
COLORS
1 x 6 x 16' 1 x 6 x 20'
XX010616TLS01 XX010620TLS01
Transcend Lineage
RN, CL, BC, JA, IM
1" Square-Edge Board Actual dimensions: Transcend & Enhance: .94 in x 5.5 in x 16 ft / 20 ft (24 mm x 140 mm x 487 cm / 609 cm)
1 x 6 x 16' 1 x 6 x 20'
XX010616TS01 XX010620TS01
Transcend Tropicals
TT, HG, SR, LR, IM
1 x 6 x 16' 1 x 6 x 20'
XX010616T2S01 XX010620T2S01
Transcend Earth Tones
RS
Approved Fasteners:
Gapping and Overhang: You must gap Trex cladding both end-to-end and width-to-width. Gapping is necessary for airflow and the slight thermal expansion and contraction of Trex cladding boards. » ALWAYS follow Trex recommended gapping guidelines. » Maximum allowable perpendicular overhang for all Trex decking is 3/4 ".
NOTE: The fasteners listed below are all approved fasteners for attachment of Trex Cladding to furring strips. Consult local building code official for proper fasteners to use when attaching furring strips to structural wall. For salt water applications, it is recommended to use wood furring strips with appropriate stainless steel screws. If any condition occurs which is attributable to the use of non-recommended fasteners, such condition shall not be covered under the Trex Limited Warranty. Cladding Attachment to Wood Furring Strips: » Starborn® Cap-Tor® xd Epoxy Coated & Headcote® 305 Stainless 2" ONLY . » Starborn Deckfast® Fascia System –Epoxy Coated & Headcote® 305 Stainless. » Starborn® Pro Plug® System for PVC and Composite (Epoxy Coated & 305 or 316 Stainless) 2" ONLY . Cladding Attachment to Steel Furring Strips: » Starborn® Pro Plug® System for PVC and Composite for Metal Framing (410SS, self-drilling). » Starborn Deckfast® Metal 410SS with Epoxy Coating.
WIDTH-TO-WIDTH GAP
3/16" Min.
END-TO-END/END-TO-WIDTH AND ABUTTING GAP
End-to-End/ End-to-Width
Abutting Solid Objects
1/8 "
1/4 "
Above 40°F* (4.5°C)*
3/16 "
1/2 "
Below 40°F* (4.5°C)*
*Temperature at installation Pro Plug ® , DeckFast ® Cap-Tor ® xd and HeadCote ® are registered trademarks of Starborn Industries Inc.
FASTENING TIPS
Install fasteners at a 90° angle (perpendicular to the board).
Install screws at minimum of 1" (25 mm) from the board end and edge, without splitting the board.