Patching Holes in Ice Rink Using a 5 gallon bucket, add snow and water to make a thick slush. Pour into hole and level with surface of ice. Stay away from patch with equipment until frozen. Directions for Use Patching — a. Fill holes as needed. b. Allow to freeze. c. Resurface as needed. Hose & Equipment Needs Per Ice Rink Location Centennial East Lower Basin:

Water Source: Hydrant Hose Requirements: 350' 2½” — 100' 1½’ — 250' Hydrant Meter (1) Hydrant Wrench (1) Reducer Y (1) Universal Spanner Wrench (1)

Gartner

Water Source: Hydrant (75th & Gartner) Hose Requirements: 300'

2½” — 3 1½” — 3 Hydrant Meter (1) Hydrant Wrench (1) 2½” — 1½” Reducer (1) Universal Spanner Wrench (1)

Commissioners

No Hydrant available 1 Ton Truck is used to fill water from South Maintenance Facilityor from quick connect located near inline hockey rink. 12 – 50’ hoses. Nike Sports Complex Hose Requirements: 950’ - initial fill Meadow Glens Hose Requirements: 950’ - initial fill