V4 Sourcebook - March 2020

Dosing - Suction

Suction Lance and Foot Valve

Foot Valve (Flexible)

Suction Lance (Fixed)

 Suits Tube sizes (4/6, 6/9, 6/12, 9/12)

 2” BSP bung hold/ suits Tube sizes (4/6, 6/9, 6/12, 9/12)

Description

CODE

Description CODE PE Body - No Level switch 9807 0952 PE Body - 2 Level switch 9807 0967 PVDF Body - No Level switch 9807 0954 PVDF Body - 2 Level switch 9807 0969

PE Body - No level switch

9807 1051

PE Body - 2 level switch

9807 1147

PVDF Body - No level switch

9807 1053

PVDF Body - 2 level switch

9807 1149

What are the benefits of a 2 Level switch setup

When the tank drops below the first switch - it sends a message to the pump screen to display a warning low light. (Pump keeps running).

When the tank drops below the second switch the pumps stops running.

No switch means the pump will keep trying to draw liquid from an empty tank

Fixed vs Level Example

 Suction Lance (Fixed Pipe work)

 Foot Valve (Flexible pipe work)

Calibration Column ( GRIFFCO)

Description Max Flow (lph)

Increments

OAL

BSP-F Connection Code

Solvent Weld Connection Code

0-100ml Cal cylinder DN25

12

1ml

279

1/2”

CAL-100G DN15 CAL-100G-SW

0-200ml Cal Cylinder

1/2”

CAL-200G DN15 CAL-200G-SW

0-300ml Cal Cylinder DN32

36

5ml

330

1/2”

CAL-300G DN15 CAL-300G-SW

0-500ml Cal cylinder DN50

60

5ml

330

3/4”

CAL-500G DN20 CAL-500G-SW

0-1,000ml Cal cylinder DN50

120

5ml

559

3/4”

CAL-1000G DN20 CAL-1000G-SW

0-2,000ml Cal cylinder DN80

240

10ml

508

1”

CAL-2000G DN25 CAL-2000G-SW

0-3,000ml Cal cylinder

1.5”

CAL-3000G DN40 CAL-3000G-SW

0-4,000ml Cal cylinder DN100

480

10ml

940

1”

CAL-4000G DN25 CAL-4000G-SW

0-10,000ml Cal cylinder DN100

1,200

100ml

635

2” CAL-10000G DN50 CAL-10000G-SW

* Max Flow is based on 30 second drawdown

232 PAAS Source Book

www.paas.com.au