EnglishIndustrialHeatingWaterCooledTransformers

INDUSTRIAL HEATING WATER-COOLED TRANSFORMERS

THE POWER TO TRANSFORM ™ RoMan Manufacturing ® is one of the world’s leading designers and manufacturers of AC water-cooled transformers and related specialty products. As a manufacturer of high-current, continuous operation transformers, we combine unparalleled knowledge and expertise with innovative technology, to deliver ready to use products to leading companies worldwide.

RoMan’s Water-cooled, fully potted transformers can be closely-coupled to the load helping to reduce electrical losses in the power delivery system, while eliminating the need for mounting cabinets. Closer to the Heat Source

SINGLE PHASE WATER-COOLED TRANSFORMERS Single phase transformers are manufactured to meet the electrical specifications of your facility and application. The transformers are engineered to provide operational reliability while operating in industrial working environments.

SCOTT-T WATER-COOLED TRANSFORMERS Scott-T transformers provide a balanced three phase

distribution of power to be used in two-phase load applications. The transformers are made in two identical configurations, allowing partial spares to be used across an installed line.

THREE PHASE WATER-COOLED TRANSFORMERS Three Phase transformers provide three phase distribution of power to the loads. Multiple configurations including Delta and Wye are available. Various mounting options are available to meet your space and size requirements.

STACK-UP SAVES SPACE Our transformer size allows them to be stacked-up and installed next to where the heat source is needed most. This reduces the need for costly transformer rooms.

RoMan transformers can be mounted on top or below the platform helping to replace large cabinetry space.

RoMan transformers can replace this footprint.

BENEFITS Because our transformers are custom-designed for your application, they electro-mechanically integrate with your power. Smaller in size and lighter in weight, they become a component of your structural system closely coupled to the heat source. This results in a substantial reduction of total energy consumption, installation, maintenance and capex costs.

MECHANICAL MOUNTINGS RoMan offers custom design and manufacturing of mechanical frames and mounting stands for all of our transformers, as well as water-cooled and air-cooled secondary conductor and isolation devices.

Customer: ________________________________ Project Number: ___________________________

ROMAN TRANSFORMER APPLICATION SHEET

Download PDF at romanmfg.com/appform

MAIN INFORMATION Primary Voltage(s): 220 230 240 380 400 415 420 440 460 480 575 Other: ____________ Variance Taps: _____________________________________________________________________________________ _ Example: +/- 5% or 10% Frequency: 50 Hz 60 Hz 50/60 HZ Other: ____________ Secondary Voltage(s) (Please list all): ______________________________________________________________________________________ _ Number of Taps: _________________________________________________________________________________________________________ Tap Location: Primary Side Secondary Side Special configuration: _ ____________________________________________________ Phase: Single Phase Primary Three Phase Primary Other: _ ___________________________________________________________ Multi Phase Primary Configuration: Three Phase Delta Wye Other: _ ____________________________________________________ Secondary Configuration: Delta Wye Scott-T Other:_______________________________________________________________ Mounting and Termination: Metric thread Imperial thread Transformer Type: Isolation Auto Other: ____________________________________________________________________________ KVA: ___________________________________________________________________________________________________________________ KVA Over Range: ________________________________ Constant Power (KVA) Constant Secondary Current over Secondary Voltage Range Certification: CE UL Recognized CSA UL Certified Other:_ _____________________________________________________ Core Rating: ______________________________________________________________________________________________ Tesla or kGauss Any Specific Testing Required: Yes No If yes, what: _____________________________________________________________________________________ Example: Hi Pot, accessories etc. Size constraints, please describe: _____________________________________________________________________________ _____________ Water or Air Cooled: Water Cooled Air Cooled

ACCESSORY INFORMATION Center Tap on Primary: Yes No Center Tap on Secondary: Yes No

Voltage Meter: Yes No Ammeter: Yes No Enclosure: Yes No If yes, what type: _____________________________________________ Example: Primary connections, secondary connections, whole unit If whole unit, what rating:______________________________________ Example: IP21, NEMA 1 Primary Connection: __________________________________________ Example: Studs, lugs terminals Secondary Connection:________________________________ _______ Example: Studs, lugs terminals Secondary Components: ______________________________________ Example: Cables, shunts, bus work (RoMan’s Non-Ferrous Foundry) Mounting: __________________________________________________ Example: Frame, hanger, lifting eyes, etc. Breaker on Transformer: Yes No Specs of Breaker: __________________________________ Specify Breaker Supplied: Yes No Secondary Voltage Sensing Wires: Yes No If yes, what type: _____________________________________ _______ Fused (at what amperage) or not fused PT on Secondary Sensing Wires: Yes No If yes, what range: ____________________________________________ Example: 120:10

CT on Secondary with Burden Resistor: Yes No CT on Secondary without Burden Resistor: Yes No If CT what range: _______________________________________ _____ Example: XXX:1, XXX:5 PT on Primary: Yes No If yes, what range: __________________________________________ _ Example: 480:120 PT on Secondary: Yes No If yes, what range: ____________________________________________ Example: 120:10 Thermoswitch: Yes No Thermocouple: Yes No If yes, what type: _____________________________________________ Example: J type, K type Water Connections:___________________________________________ Example: Individual circuits or manifold Flow Switch: Yes No Flow Monitor: Yes No If yes, what type: _____________________________________________ Example: Visual, Digital

For more information

Grand Rapids, MI | 616.530.8641 | romanmfg.com

5-2017

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6

Made with FlippingBook Annual report