Inductive coupler M30-8
Contact free transmission of energy and signals
■ Stationary unit - Base ■ Mobile unit - Remote
Axial coupler
B
Base:
E
C
D
3x LED
3 2
4
10
1
11
5
9
12
6
7 8
Male connector 12 pin
36
B
Remote:
D
C
E
3x LED
2 3
4
10
1
11
5
9
12
6
8 7
Female connector 12 pin
36
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupler M30-8
Base
Remote
SMW-Electronics Type Id. No. Thread
0E011602 M30 x 1.5
0E011603 M30 x 1.5
A B C D
mm mm mm mm mm mm mm
98 52 13
98 52 13
E F
14.5
14.5
M12x1 / Male
M12x1 / Female
G
Ø 27
Ø 27
Housing material Protection class Operating temperature Storage temperature
CuZn, PA66, PC GF 30%
CuZn, PA66, PC GF 30%
IP 67
IP 67
-20°C ... +80°C -20°C ... +80°C 0 mm ... 8 mm*
-20°C ... +80°C -20°C ... +80°C 0 mm ... 8 mm*
Coupling distance Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple
24V (18 ... 30V)
-
-
24V ± 10% DC
< 500mA
-
-
< 100mA
✓
✓
-
< 200mV
✓ ✓
-
Reverse polarity protection Temperature monitoring Data-Valid Output Operational readiness PIN assignment
✓
150mA
-
< 300 ms
< 300 ms
PIN 1
Signal Base
Signal Remote
Supply voltage Digital signal 1 Digital signal 2 Digital signal 3 Digital signal 4 Digital signal 5 Digital signal 6 Digital signal 7 Digital signal 8 Ground connection Data-Valid -
24V IN
24V OUT 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN
2 3 4 5 6 7 8 9
0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT
10 11 12
GND
GND
0 / 24V OUT
- -
-
* Up to 12 mm with reduced power
SMW-AUTOBLOK 11
Made with FlippingBook Publishing Software