Preview_electronics_F180+M30_27_05_21_EN

Inductive coupler M30-8

Contact free transmission of energy and signals

■ Stationary unit - Base ■ Mobile unit - Remote

Axial coupler

B

Base:

E

C

D

3x LED

3 2

4

10

1

11

5

9

12

6

7 8

Male connector 12 pin

36

B

Remote:

D

C

E

3x LED

2 3

4

10

1

11

5

9

12

6

8 7

Female connector 12 pin

36

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupler M30-8

Base

Remote

SMW-Electronics Type Id. No. Thread

0E011602 M30 x 1.5

0E011603 M30 x 1.5

A B C D

mm mm mm mm mm mm mm

98 52 13

98 52 13

E F

14.5

14.5

M12x1 / Male

M12x1 / Female

G

Ø 27

Ø 27

Housing material Protection class Operating temperature Storage temperature

CuZn, PA66, PC GF 30%

CuZn, PA66, PC GF 30%

IP 67

IP 67

-20°C ... +80°C -20°C ... +80°C 0 mm ... 8 mm*

-20°C ... +80°C -20°C ... +80°C 0 mm ... 8 mm*

Coupling distance Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple

24V (18 ... 30V)

-

-

24V ± 10% DC

< 500mA

-

-

< 100mA

-

< 200mV

✓ ✓

-

Reverse polarity protection Temperature monitoring Data-Valid Output Operational readiness PIN assignment

150mA

-

< 300 ms

< 300 ms

PIN 1

Signal Base

Signal Remote

Supply voltage Digital signal 1 Digital signal 2 Digital signal 3 Digital signal 4 Digital signal 5 Digital signal 6 Digital signal 7 Digital signal 8 Ground connection Data-Valid -

24V IN

24V OUT 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN 0 / 24V IN

2 3 4 5 6 7 8 9

0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT 0 / 24V OUT

10 11 12

GND

GND

0 / 24V OUT

- -

-

* Up to 12 mm with reduced power

SMW-AUTOBLOK 11

Made with FlippingBook Publishing Software