Inductive coupler M30-IOL
Contact free transmission of energy and signals
Axial coupler
Application/customer benets • Contact free transmission of energy and signals between stationary and moved components • Application examples: Supply of sensors, supply and monitoring of remote systems • Dynamic Pairing • Wear and maintenance free • Protective function: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting M30 x 1.5 • Supply voltage 24V (18 ... 30V) • Transmission distance 0 - 12 mm • Transmission of energy: 24V / 12W (500mA) • Transmission of signals: IO-Link COM1, COM2, COM3 fully transparent • Id. No. Base: 0E011604 Id. No. Remote: 0E011605 • Interface: Remote female connector M12x1 (4-pin), base male connector M12x1 (5-pin) • Additional digital-switching signal from Remote » Stat. is transmitted
Block diagram:
IO-Link Master
24V / 18W
Energy
IO-Link-Device
0 - 8 mm
Base
Remote
Signals
IO-Link
Subject to technical changes. For more detailed information please ask our customer service.
Function Base LED Power Color
Function Remote LED Coupling Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » 24V ok and mobile unit has been detected Flashes 2Hz green » 24V ok but no mobile unit detected Flashes 1Hz red / green » Incompatible mobile unit detected Flashes 2Hz red » Foreign object detected Flashes 5Hz red » Internal error
Off » Unit is not connected On (green) » Unit coupled, voltage output DC24V ok Flashes 2Hz red » Connected but short-circuited at DC24V Flashes 5Hz red » Internal error
Function
Function
LED IO-Link Color
Green / red
LED IO-Link Color
Green » Signals IO-Link operation according to IO-Link specication (1000ms on / 100ms off)
Green / red
Green » Signals IO-Link operation Green » On (SIO Mode Signal on) Green » Off (SIO Mode Signal off) Flashes 2Hz red » Short circuit at the IO-Link PIN Flashes 5Hz red » Overload voltage output remote unit
Green » On (SIO Mode Signal on) Green » Off (SIO Mode Signal off) Flashes 2Hz red » Short circuit at the IO-Link PIN Flashes 5Hz red » Overload voltage output mobile unit
Function
Function
LED Signal 2 Color
Yellow
LED Signal Color
Yellow / red
Off » Digital input 2 is not connected or no mobile unit detected On / yellow » Digital input 2 is connected
Function
Off » Digital input is not connected or no mobile unit detected On / yellow » Digital input is connected Flashes 2Hz red » Digital input is connected but short circuit at the output Flashes 5Hz red » Overload voltage output mobile unit
Function
12 SMW-AUTOBLOK