Preview_electronics_F180+M30_27_05_21_EN

Inductive coupler F180 Ethernet

Contact free transmission of energy and signals

■ Stationary unit - Base ■ Mobile unit - Remote

Axial coupler

Base / Remote:

Base:

Remote:

C

C

H

H

H1

H1

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupler F180 Ethernet

Base

Remote

SMW-Electronics Type Id. No.

0E011246

0E011247

A B

mm mm mm mm mm mm mm mm mm

180

180

85 93

85 93

B1

C D

29.5

29.5

57 20

57 20

E F

5

5

H

34

34

H1

7

7

ɑ

60

60

degree

Housing material Protection class

Aluminium, GFK

Aluminium, GFK

IP 67

IP 67

Function Base LED Power Color

Function Remote LED Actuator Color

Green / red

Green / red

Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2Hz green 50 / 50% » Operating temperature in critical range 1Hz green 25 / 75% » Voltage ok but no mobile unit detected 1Hz red / green » Incompatible mobile unit detected 2Hz red » Foreign element detected 5Hz red » Internal error

Off » Unit not paired On (green) » Unit paired, voltage output actuator (48V) ok Flashes 2Hz red » Unit paired but short circuit on actuator (48V) Flashes 5Hz red » Internal error

Function

Function

LED Sensor supply Color

Green / red

Off » Unit not paired On (green) » Unit paired, voltage output sensor (24V) ok Flashes 2Hz red » Unit paired but short circuit on sensor (24V) Flashes 5Hz red » Internal error

LED Signal transmission Ethernet Color Yellow / red

Function

Off » No mobile unit detected On / yellow » Signal transmission ready 1Hz yellow » Data packets are being transmitted

LED Signal transmission Color Yellow / red

Function

3Hz yellow » 50% of the transmission bandwidth used (10s) 8Hz red » Data packets were discarded (in the last 10s) On / red » Error in data transmission (internal error)

Off » No mobile unit detected On / yellow » Signal transmission ready

Flashes 1Hz yellow » Data packets are being transmitted Flashes 3Hz yellow » 50% of the transmission bandwidth used (10s) Flashes 8Hz red » Data packets were discarded (in the last 10s) On / red » Error in data transmission (internal error)

LED Energy transmission Color Yellow / red

Function

Off » No mobile unit detected On (yellow) » Unit coupled, voltage output ok

1Hz red / yellow » Short circuit at voltage output sensor 3Hz red / yellow » Short circuit at voltage output actuator 3Hz red » Short circuit at both voltage outputs 5Hz red » Internal error

Function

SMW-AUTOBLOK 3

Made with FlippingBook Publishing Software