Preview_electronics_F180+M30_27_05_21_EN

Inductive coupler F180 Ethernet / CAN

Contact free transmission of energy and signals

■ Stationary unit - Base ■ Mobile unit - Remote

Axial coupler

Base / Remote:

Base:

Remote:

C

C

H

H

H1

H1

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupler F180 Ethernet / CAN

Base

Remote

SMW-Electronics Type Id. No.

0E011244

0E011245

A B

mm mm mm mm mm mm mm mm mm

180

180

85 93

85 93

B1

C D

29.5

29.5

57 20

57 20

E F

5

5

H

34

34

H1

7

7

ɑ

60

60

degree

Housing material Protection class Function Base LED Power Color

Aluminium, GFK

Aluminium, GFK

IP 67

IP 67

Function Remote LED Actuator Color

green / red

Green / red

Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2Hz green 50 / 50% » Operating temperature in critical range 1Hz green 25 / 75% » Voltage ok but no mobile unit detected 1Hz red / green » Incompatible mobile unit detected 2Hz red » Foreign element detected 5Hz red » Internal error

Off » Unit not paired On (green) » Unit paired, voltage output actuator (48V) ok Flashes 2Hz red » Paired but short circuit on actuator (48V) Flashes 5Hz red » Internal error

Function

Function

LED Sensor supply / CAN Color Yellow / red

Off » Unit not paired On (yellow) » Unit paired, voltage output ok 2Hz yellow (75% / 25%) » CAN data is being transmitted (last 2s) 5Hz red » Internal error

LED Signal transmission Ethernet Color Yellow / red

Function

Off » No mobile unit detected On / yellow » Signal transmission ready 1Hz yellow » Data packets are being transmitted

LED Signal transmission Ethernet Color Yellow / red

Function

3Hz yellow » 50% of the transmission bandwidth used (10s) 8Hz red » Data packets were discarded (in the last 10s) On / red » Error in data transmission (internal error)

Off » No mobile unit detected On / yellow » Signal transmission ready 1Hz yellow » Data packets are being transmitted

LED Signal transmission CAN Color Yellow / red

3Hz yellow » 50% of the transmission bandwidth used (10s) 8Hz red » Data packets were discarded (in the last 10s) On / red » Error in data transmission (internal error)

Function

Off » Unit not paired On (yellow) » Unit coupled, voltage output ok 2Hz yellow (75% / 25%) » CAN data is being transmitted (last 2s) 5Hz red » Internal error

Function

SMW-AUTOBLOK 5

Made with FlippingBook Publishing Software