Inductive coupler M30-2
Contact free transmission of energy and signals
Axial coupler
Application/customer benets • Contact free transmission of energy and signals between stationary and moved components • Application examples: Supply of sensors, supply and monitoring of remote systems, contactless battery charge (W-Charge), monitoring of door contacting, valve control, plug replacement • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting M30 x 1.5
• Supply voltage 24V (18 ... 30V) • Transmission distance 0 - 12 mm • Transmission of energy: 24V / 12W (500mA) • Transmission of signals: 2 digital signals • Id. No. Base: 0E011600 Id. No. Remote: 0E011601 • Interface: Remote female connector M12x1 (4-pin), base male connector M12x1 (4-pin)
Block diagram:
Control
24V / 18W
1 digital signal
Energy
0 - 12 mm
Base
Remote
Signals
Subject to technical changes. For more detailed information please ask our customer service.
Function Base LED Power Color
Function Remote LED Coupling Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » 24V ok and remote unit has been detected Flashes 2Hz green » 24V ok but no remote unit detected Flashes 1Hz green / red » Incompatible remote unit detected Flashes 2Hz red » Foreign object detected Flashes 5Hz red » Internal error
Off » Unit is not connected On (green) » Unit is connected, voltage output DC24V ok Flashes 2Hz red » Unit is connected but short circuit at DC24V Flashes 5Hz red » Internal error
Function
Function
LED Signal 1 Color
Yellow
LED Signal 1 Color
Off » Digital input 1 is not connected On / yellow » Digital input 1 is connected
Function
Yellow / red
LED Signal 2 Color
Off » Digital input 1 is not connected or no remote unit detected
Yellow
On / yellow » Digital input 1 is connected Flashes 2Hz red » Digital input connected but short circuit at the output Flashes 5Hz red » Overload voltage output remote unit
Off » Digital input 2 is not connected On / yellow » Digital input 2 is connected
Function
Function
LED Signal 2 Color
Yellow / red
Out » Digital input 2 is not connected or no remote unit detected
On / yellow » Digital input 2 is connected Flashes 2Hz red » Digital input connected but short circuit at the output Flashes 5Hz red » Overload voltage output remote unit
Function
8 SMW-AUTOBLOK
Made with FlippingBook Publishing Software