Preview_electronics_F180+M30_27_05_21_EN

Inductive coupler M30-2

Contact free transmission of energy and signals

Axial coupler

Application/customer benets • Contact free transmission of energy and signals between stationary and moved components • Application examples: Supply of sensors, supply and monitoring of remote systems, contactless battery charge (W-Charge), monitoring of door contacting, valve control, plug replacement • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting M30 x 1.5

• Supply voltage 24V (18 ... 30V) • Transmission distance 0 - 12 mm • Transmission of energy: 24V / 12W (500mA) • Transmission of signals: 2 digital signals • Id. No. Base: 0E011600 Id. No. Remote: 0E011601 • Interface: Remote female connector M12x1 (4-pin), base male connector M12x1 (4-pin)

Block diagram:

Control

24V / 18W

1 digital signal

Energy

0 - 12 mm

Base

Remote

Signals

Subject to technical changes. For more detailed information please ask our customer service.

Function Base LED Power Color

Function Remote LED Coupling Color

Green / red

Green / red

Off » Unit not supplied with voltage (or undervoltage) On (green) » 24V ok and remote unit has been detected Flashes 2Hz green » 24V ok but no remote unit detected Flashes 1Hz green / red » Incompatible remote unit detected Flashes 2Hz red » Foreign object detected Flashes 5Hz red » Internal error

Off » Unit is not connected On (green) » Unit is connected, voltage output DC24V ok Flashes 2Hz red » Unit is connected but short circuit at DC24V Flashes 5Hz red » Internal error

Function

Function

LED Signal 1 Color

Yellow

LED Signal 1 Color

Off » Digital input 1 is not connected On / yellow » Digital input 1 is connected

Function

Yellow / red

LED Signal 2 Color

Off » Digital input 1 is not connected or no remote unit detected

Yellow

On / yellow » Digital input 1 is connected Flashes 2Hz red » Digital input connected but short circuit at the output Flashes 5Hz red » Overload voltage output remote unit

Off » Digital input 2 is not connected On / yellow » Digital input 2 is connected

Function

Function

LED Signal 2 Color

Yellow / red

Out » Digital input 2 is not connected or no remote unit detected

On / yellow » Digital input 2 is connected Flashes 2Hz red » Digital input connected but short circuit at the output Flashes 5Hz red » Overload voltage output remote unit

Function

8 SMW-AUTOBLOK