BUILDING SPECIFICATIONS
Full Block on West Side of Eighth Avenue Between 49th and 50th Streets
Twenty two (22) destination dispatch passenger elevators, three (3) freight elevators and two (2) loading dock truck elevators Four (4) escalators Loading dock located on 50th Street DX package AC units located on each non-Nomura floor. • Floors 11-14 Two (2) 60-ton units • Floor 17 Two (2) 50-ton units • Floor 18 Two (2) 50-ton units • Floors 20-48 One (1) 60-ton units • Floor 49 One (1) 45-ton units The heating system consists of high pressure utility company steam service.
location
vertical transportation
1989. Renovated in 2013
year built
Skidmore, Owings & Merrill, LLP - David Childs
architect
hvac / supplemental cooling
2,051,943 rsf
building size
Forty nine (49) floors
building height
• Conventional structural steel beams and columns with reinforced concrete floor slabs • The exterior walls are finished with brick masonry veneer surrounding aluminum framed “punched” windows. The lower floors are finished with a granite veneer, and the Building’s base includes precast concrete on tower corners and stone surrounding the large entrance openings
building construction
Six (6) 4,000 amp services at 277/480 volts Eight (8) watts/SF available for tenant use
electric
life / safety
Center core
Addressable Class E system Building is fully sprinklered
floor layout
50 lbs. psf
floor load
Emergency generator covering all life safety systems 400-425kW excess capacity available for tenant tie-in Location available for 1,000kW tenant generator
generators
Floor 2 Floor 4
36,000 rsf 72,400 rsf 54,800 rsf 47,500 rsf
floor sizes
Floors 5-6 Floors 7-14 Floors 15-19 Floors 20-47
security / access
Coordinated program of controlled electronic access, electronic surveillance and uniformed security guards on a 24/7 basis, electronic turnstiles, messenger center and extensive CCTV coverage
40,000 - 42,000 rsf 32,500 - 34,500 rsf
Floor 48 Floor 49
24,300 rsf 20,500 rsf
telecom / cable
AT&T, Century Link, Cogent, Crown Castle/Lightower, RCN, Spectrum, Verizon, Zayo Group Wired Certified Platinum DAS for enhanced cellular service
13’
typical slab heights
Column free tower floors (20-49) Virtually column free base floors (2-19)
column spacing
Direct access to C & E subway lines
transportation