Table 2. European Standards for the Nominal Properties for Particleboard, Medium Density Fiberboard, and Hard Density Fiberboard Specifications F m E m TS (Description, thickness) (MPa) (MPa) (%) Particleboard (PB): 1 General Purpose boards/dry conditions (P1), 3 to 6 mm 14 -- -- Boards for interior fitments (including furniture)/dry conditions (P2), 3 to 4 mm 13 1800 -- Boards for interior fitments (including furniture)/dry conditions (P2),>4 to 6 mm 14 1950 -- Non-load-bearing boards/humid conditions (P3), 3 to 4 mm 13 1800 17 Non-load-bearing boards/humid conditions (P3), >4 to 6 mm 14 1950 16 Non-load-bearing boards/humid conditions, 3 to 4 mm -- -- 15 Non-load-bearing boards/humid conditions, >4 to 6 mm -- -- 14 Load-bearing boards/dry conditions (P4), 3 to 4 mm 15 1950 23 Load-bearing boards/dry conditions (P4), >4 to 6 mm 16 2200 19 Load-bearing boards/humid conditions (P5), 3 to 4 mm 20 2550 13 Load-bearing boards/humid conditions (P5), >4 to 6 mm 19 2550 12 Medium Density Fiberboards (MDF): 2 General Purpose boards/dry conditions (MDF), >2.5 to 4 mm 23 -- 35 General Purpose boards/dry conditions (MDF), >4 to 6 mm 23 2700 30 General Purpose boards/humid conditions (MDF.H), >2.5 to 4 mm 27 2700 30 General Purpose boards/humid conditions (MDF.H), >4 to 6 mm 27 2700 18 Load-bearing boards/dry conditions (MDF.LA), >2.5 to 4 mm 29 3000 35 Load-bearing boards/dry conditions (MDF.LA), >4 to 6 mm 29 3000 30 Load-bearing boards/humid conditions (MDF.HLS), >2.5 to 4 mm 34 3000 30 Load-bearing boards/humid conditions (MDF.HLS), >4 to 6 mm 34 3000 18 Hardboard Fiberboard (HB): 3 General Purpose boards/dry conditions, d 3.5 mm 30 -- 35 General Purpose boards/dry conditions, >3.5 to 5.5 mm 30 -- 30 General Purpose boards/humid conditions, d 3.5 mm 35 -- 25 General Purpose boards/humid conditions, >3.5 to 5.5 mm 32 -- 20 General Purpose boards/exterior (HB.E), d 3.5 40 3600 12 General Purpose boards/exterior (HB.E), >3.5 to 5.5 mm 35 3200 10 Load-bearing boards/dry conditions (HB.LA), d 3.5 33 2700 35 Load-bearing boards/dry conditions (HB.LA), >3.5 to 5.5 32 2500 30 Load-bearing boards/humid conditions (HB.HLA1), d 3.5 to 5.5 38 3800 15 Load-bearing boards/humid conditions (HB.HLA1), >3.5 to 5.5 36 3600 13 Heavy-duty load-bearing boards/humid conditions (HB.HLA2), d 3.5 to 5.5 44 4500 15 1 EN 312:2003, 2 EN 622-5:2006, 3 EN 622-2:1997.

2695

Tisserat et al . (2018). “DDGS - PW fiberboards” B io R esources 13(2), 2678-2701.

Made with FlippingBook Ebook Creator