GARN® GN2000 WHS | Operator Manual

UNPACKING AND ASSEMBLY : INDUCED DRAFT FACE MOUNTED BLOWER ASSEMBLY

10. The bent flow stabilizer should be pushed as far as possible into the upper cleanout with the bend at 3 o’clock.

11.Position the upper clean out gasket and upper clean out cover on the blower housing. Hold the assembly in place and install 3/8-16 castellated nuts. Tighten the nuts securely, compressing the gasket SLIGHTLY . 12. It is now safe to temporarily plug in the blower motor to check its operation. The motor should operate without any rubbing or grinding noise. Significant air flow should exit from the exhaust flue at the rear of the GARN® WHS unit.

Review the motor manufacturer’s literature packaged with the motor for proper care and maintenance.

GARN WHS 1000 and WHS 2000 Manual © HY-C Company LLC - September 2024

16

Made with FlippingBook - professional solution for displaying marketing and sales documents online