INSTALLATION : EXHAUST FLUE INSTALLATION
HORIZONTAL FLUE CONNECTION: USA or CANADA
Step 1: Insert the flue into the collar and over the positioning ring that is welded to the unit. Hold the flue firmly in position and install the provided sheet metal screws to secure the flue to the collar.
Step 2: Pack the provided stove rope into the area between the flue and the collar. Use a paint mixing stick or other object to pack the rope. Continue packing the area in a circular fashion. Use all of the stove rope.
43
GARN® WHS 1000 and WHS 2000 Manual | © HY-C® Company LLC | October 2024