INSTALLATION : GARN® WHS/ETS DIGITAL CONTROLLER
SPLIT MANWAY COVER Units produced after September 2015 are shipped with a “split” manway cover. The split manway cover is a new generation manway cover that adds a number of benefits to the previous spun cover design. The split cover comes with a high-temperature, full-face gasket. The gasket protects the galvanized cover and soft gasket from corrosion and wear and will provide years of service for both gaskets. The split cover is separated into two pieces allowing the operator to look inside the tank without disturbing the float sensor switch. Older units will have the spun cover but a split cover can be purchased from www.garnparts.com and will retrofit to any GARN® WHS unit purchased after 1989. The split cover is part # P-122 and is made up of the following components:
INSTALLING THE SPLIT MANWAY COVER: 1. This shows what is provided with the split manway cover kit P-0122: large and small Teflon discs; two galvanized cover sections with adhered black perimeter gasket; & two zip ties.
2. Position the cover with the 4 tabs down . Feed the zip ties thru the holes provided. Tighten slowly confirming hinge action.