GARN® GN2000 WHS | Operator Manual

6. Blow out the loose material from the holes. 7. Align the wheel puller over the hub and screw the two ¼-20 hex bolts into the two threaded holes. Be sure the bolts extend into the hub at least ¼” . 8. Snug the center bolt tight.

9. Gently holding the wheel, tighten the center screw. The wheel should slide off the motor shaft. Be careful not to drop the wheel as it disengages from the shaft. Also do not lose the square steel key. The wheel and hub can now be cleaned using a degreaser. Rinse and set the wheel aside. 10.Remove the motor gasket and clean the mounting plate. Replace the gasket and/or the motor, as required. 11. Clean the motor shaft and apply a hi-temp anti seize compound to the shaft and internal bore of the hub. 12. Reinstall the blower assembly according to the “ Induced Draft Face Mounted Blower Assembly ” section of this manual.

GARN WHS 1000 and WHS 2000 Manual © HY-C Company LLC - September 2024

94

Made with FlippingBook - professional solution for displaying marketing and sales documents online