2021 MILA Product Catalog

59

Airway/ET Tube Exchange Catheter

Atomizer/Throat Sprayer

Deliver topical anesthetic to the nose, throat, hypopharynx, vocal cords, larynx and trachea prior to airway manipulation such as intubation, endoscopy, rhinoscopy and soft palate exam. The benefit is a reduced gag and sensation, reduced pulse and blood pressure response to intubation. • A tomize medication into a fine mist of particles 50-80 microns. • 1 5Fr (4.7mm) tip x 6.5 inch (15cm) malleable, conformable tube for targeted deposition of medication. • 5 cc syringe is recommended for accurate dosing and proper pressure. • P riming volume is 0.2ml. • U se a 3ml syringe for a minimum forecast distance of 100mm upon exiting the sprayer tip under 25Kpa pressure to form an area of diameter of no less than 70mm. ITEM#5380 $4.75 “The device makes endoscopy work

• Intended for uncomplicated atraumatic endotracheal tube exchange. • U seful for oxygenating during fluoroscopy. • 1 5mm adapter for temporary oxygen delivery, NOT for ventilating the patient. • 1 5mm adapter is removed to slide ET tubes out and in. • C entimeter markings for alignment with endotracheal tube markings. • P olished, atraumatic, open-ended catheter with side holes. DESCRIPTION ITEM#

PRICE $28.00 $28.00 $28.00 $28.00

8Fr x 80cm (32in) 10Fr x 80cm (32in) 10Fr x 150cm (60in) 15Fr x 80cm (32in)

ETE0880 ETE1080 ETE10150 ETE1580

within the nasal cavity, soft palate, larynx and pharnyx much easier by distributing a fine mist of lidocaine or lidocaine/ phenylephrine.” “We also use the device to distribute same mixture in hard to reach surgical areas such as otic canals, wound flaps,

urogenital tracts, and to atomize topical local anesthetics and hemostatic agents to bleeding tumors and derm biopsy sites.” Andrea Looney, DVM, DACVAA, DACVSMR Anesthesia Services, IVG Hospitals,Woburn, MA

Double Swivel Tracheal Tube Connector with Capped Port, 15mm N E W ★

Designed to facilitate introduction of fiber optic bronchoscope during mechanical ventilation. • S ilicone port with cap allows easy passage of fiber optic scope for bronchoscopy. • A llows for suction catheter without disconnecting from ventilator. • M aintains seal around scope during bronchoscopy procedure. Seal accepts bronchoscope diameters from 3.4 to 5.9mm. • 360 º Double Swivel Feature: Both the male and female 15mm connectors allow greater patient maneuverability between endotracheal tube and anesthesia circuit. ITEM#SC15MM $7.00

Port for Bronchoscope

Connect to Anesthesia Circuit

Connect to Endotracheal Tube

www.milaint.com

Made with FlippingBook Annual report