Wireless Pressure Monitor
© VEKTEK, LLC 2022
Wireless Pressure Monitor The Guardian gives you pre-machining, post-machining or it can take a sample confirming hydraulic pressure while in the machine. The Guardian is the simplest, least expensive and most dependable wireless monitoring system to install and maintain. No transmitter pairing is required -- add new fixtures easily and hassle free. Guardian’s sealed system ensures positive pressure monitoring even in the harshest environments. Best of all, you will enjoy pressure monitoring with no interference issues. Easy, Simple, Dependable
MACHINE TOOL RECEIVER
MASTER CONTROL UNIT
FIXTURE TRANSMITTER
FOCUSED FIELD COMMUNICATIONS
Fixture Transmitters require NO batteries, EVER! Fully sealed polycarbonate Fixture Transmitter for service in the harsh machine environment. Polling of active fixture status before indexing, never index an unclamped fixture into your machine. Will not affect other wireless systems in your plant. Simplified connection via standard waterproof connectors and cables. Master Control Unit can communicate pressure confirmation to your CNC Controller. Master Control Unit power requirements; 10-36 VDC from Machining Center.
MASTER CONTROL UNIT
MACHINE TOOL RECEIVER
FIXTURE TRANSMITTERS
KNOW WHEN A FIXTURES PRESSURE DROPS BELOW A PREDETERMINED SETTING
DISPLAYED AND COMMUNICATED BY MASTER CONTROL UNIT
The Basics Of Guardian Operation: Step 1. Install Vektek pressure switches on fixture. Step 2. Find a place and mount your Fixture Transmitter. Step 3. Find a location for your Machine Tool Receiver. Step 4. Wire your Master Control Unit with just four wires. Step 5. No more tool crashes! IT IS THAT SIMPLE.
What does Guardian read and confirm? The Vektek Guardian pressure monitoring system is designed to confirm that pressure is above a pre-set minimum. This can be done before indexing or while inside the machine. Typical checking is done at the load station before loading a fixture into the machine. Inside the machine sampling requires the fixture to be in a known location and between machine operations without coolant and spindle interference.
What if I want to check a pallet before it goes into the machine?
The simplicity of the Guardian allows for additional remote Machine Tool Receivers to engage with the Fixture Transmitter at any point it is in range. You can confirm pressure as a pallet is removed from storage, while it is on the way to the machine or even just before indexing.
Attributes & Advantages!
How does Guardian know what transmitter to read? The Guardian uses a focused field
How do I set the pressure switch to notify my Guardian that pressure is below the critical set point? The pressure switch needs to be set to the predetermined “critical pressure” where part quality or stability may be affected. If your system pressure is 4000 psi and there is a minimum pressure to make good parts at 3000 psi, it should be set to send an alarm just above the 3000 psi reading. Note: The pressure setter/checker will help measure pressure when falling. The switch is adjusted to break continuity at some level above 3000 psi in this example. It is unreliable to set the declining pressure by adjusting while pressure is rising. Likewise, it is not recommended that pressure is adjusted too close to the operating pressure as temperature fluctuation may cause a false loss of pressure signal (we recommend at least 300-500 psi allowable drop from the stable pressure after adiabatic fluctuation is stable.) Guardian Maintenance The entire Guardian system is designed to be nearly maintenance free. All of the units require no scheduled maintenance. The Fixture Transmitter and Machine Tool Receiver should be inspected occasionally to check for damage to the enclosures. If they are damaged, they should be replaced.
communications bubble to monitor a fixed area with limited dimensions. Typically, the focused area is the loading station or a known location within the interior of a machine tool enclosure. The Guardian Receiver is typically mounted toward the top of the enclosure pointed down toward the fixture and its transmitter. Once the fixture and transmitter enter the focused field it is actively monitored (As shown in the illustration). How do I “pair” a transmitter to receiver? The Guardian pallet pressure monitoring system does not need to be paired with the Fixture Transmitter. The focused field communication bubble engages once the components enter the focused field. This allows for simple addition of any fixture with a Guardian Fixture Transmitter. Why are the transmitters unpaired? The reason for “unpaired” transmitters is Guardian’s focused field technology. Rather than being limited to a maximum of 8/12/24 or 32 paired (or readable) units, the Guardian has unlimited reading rights to its unpaired Fixture Transmitters. Only one unit within the focused field can be read at one time, however thousands of transmitters may be brought into reading range over time WITHOUT the time, effort and inconvenience of “pairing.” After all, the basic function is not to see ALL the transmitters, only to WATCH the transmitter while in the machine or load station! What about battery failures? The Guardian Fixture Transmitter has no batteries, so you will never need to be concerned about battery replacement or maintenance. The Fixture Transmitter is powered by advanced energy harvesting technology. The Master Control Unit and Machine Tool Receiver are powered by their connection to the Machine Tool, so never any battery replacements.
www.vektek.com
Mounting considerations for installing Fixture Transmitter and Machine Tool Receiver The Fixture Transmitter should be mounted for line-of-sight communication with the Machine Tool Receiver. The focused field of the Guardian identifies the Fixture Transmitter being monitored. The Machine Tool Receiver should be mounted to provide the best possible clear path of communication with the Fixture Transmitter and within 6 feet of the pallet being checked. The Guardian Fixture Transmitters should be mounted where they are not directly in the line of high-pressure coolant spray. The label on the front of the Machine Tool Receiver should face the monitored area where the Fixture Transmitter will be located.
CORRECT LINE OF SIGHT TRANSMITTER PLACEMENTS
MACHINE TOOL RECEIVER
The illustrations show the BEST transmitter locations; however, only one Fixture Transmitter per fixture is recommended.
6 ft or Less
Focused Field of Communication
CORRECT LINE OF SIGHT TRANSMITTER PLACEMENTS
Limited Communication (Not Recommended)
Things to Consider 1. Where are the M-Code terminals on your machine, and do you have any currently available ? 2. What are your best choice for communication terminals, are they available or will you need to tie into currently dedicated Door Closed, E-Stop or Feed Hold relays? 3. Is your machine positive or negative case ground (which is switched on/off) ? 4. What length of cables is going to be necessary to mount the Machine Tool Receiver to the Master Control Unit ? 5. For the best operator visibility to the status display, where will the Guardian Master Control Unit be mounted?
6. What location in the machine enclosure will you put the Guardian Machine Tool Receiver that has clear line-of-sight and will not be hit by the pallet or spindle ? 7. Where will you locate the Guardian Fixture Transmitters on your pallet that is visible to the focused field ? 8. What is the critical pressure lower limit at which you want to prevent machining ? 9. Will you need help from your Machine Tool Distributor’s service staff or does your staff have the ability to install the Guardian ?
4X 5
2X 8.5 4X 4.6
Fixture Transmitters
Operation
15
40
65.79
Guardian Simple Model 1. Wire the Simple Guardian to the control terminals that you want to use to prevent low pressure condition operation. 40 2X 8.5 4X 4.6 4X 5 40 2X 8.5 4X 4.6 4X 5 15
25.39
Fixture Transmitters 12.89
M8 PRESSURE SWITCH CONNECTION
Fixture Transmitters
43-3011-13
43-3011
120.42
15
65.79
65.79
62
2. Adjust the pressure switch to send a fault signal at critical pressure using the Pressure Setter/Checker when pressure is falling. 3. When pressure is detected, a go signal can be given to the door closed switch or other input choice. Or write the “call” into your program if using an “M” code confirmation as often as you want to monitor, this is typically done during tool changes with coolant off to reduce interference and costly demand on production time. 120.42 6.5 75.4 150.79 62 24.29 VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT M8 PRESSURE SWITCH CONNECTION 12.89 120.42 6.5 75.4 150.79 62 24.29 M8 PRESSURE SWITCH CONNECTION 12.89 25.39
24.29
25.39
43-3011-13 One Circuit 43-3011-13 43-3011-13
43-3011-04 43-3011-04 Two Circuits 43-3011-04
ILMV330117 REV C 43-3011-05 Three or Four Circuits 43-3011-05
75.4
6.5
150.79
VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT
Guardian Fixture Transmitters Select the appropriate Fixture Transmitter to monitor 1, 2, 3 or 4 circuits.
43-3011-05
43-3011-05
ILMV330117 REV C
ILMV330117 REV C
www.vektek.com
MASTER CONTROL UNIT DIMENSIONS
6.54”
3.54
1.73
LCD DISPLAY
4.17
7.87
DIN RAIL MOUNT
6.30
7.01
NAVIGATION BUTTONS
2.71
M12 5 PIN FEMALE COMMUNICATION CONNECTION TO MACHINE TOOL RECEIVER (32.8 FT CABLE INCLUDED)
M12 8 PIN MALE CONNECTION FOR MACHINE FEEDBACK (32.8 FT CABLE INCLUDED)
GUARDIAN MASTER CONTROL UNIT MODEL NO. (33-0110-14/33-0110-24/33-0110-34) M12 8 PIN MALE CONNECTOR PINOUT
PIN 3
PIN 2
PIN NUMBER WIRE COLOR FUNCTION 1 WHITE 0V 2 BROWN +10-36 VDC 3 GREEN GUARDIAN MASTER CONTROL UNIT M12 8 PIN MALE CONNECTOR WIRING
PIN 1
PIN 4
PIN 5
PIN 7
CONDITION RELAY RELAY COMMON
4 5 6 7 8
YELLOW
PIN 6 M12 8 PIN MALE PIN 8
GRAY PINK BLUE
N/A N/A N/A N/A
CONNECTOR END VIEW MASTER CONTROL UNIT
RED
5.00
MACHINE TOOL RECEIVER
3.00
5.00
5.90
5.65
1.00
5.40
2X 1.26 HIGH FORCE MAGNET
2X .28 THRU MOUNTING HOLE
.32
.08
Positionable 0-180
5.65
2.30
1.63
M12 5 Pin Male Communication Port
2.36
4.72
Point this face towards fixture transmitter
ILS330115 REV D
Vektek P/N 33-0111-02 machine tool receiver with adjustable bracket mounting dimensions 4X 5
2X 8.5 4X 4.6
Fixture Transmitters
15
40
65.79
FIXTURE TRANSMITTER 4X 5 4X 5
AVAILABLE IN ONE TO FOUR CIRCUIT MODELS
25.39
2X 8.5 4X 4.6
2X 8.5 4X 4.6
Fixture Transmitters 12.89
M8 PRESSURE SWITCH CONNECTION
Fixture Transmitters
43-3011-13
43-3011-04
120.42
15
15
4X Ø 0.18 2X Ø 0.33
4X Ø 0.20
40
65.79
40
65.79
0.59
62
24.29
25.39
25.39
1.57
2.59
12.89
12.89
M8 PRESSURE SWITCH CONNECTION
43-3011-13 One Circuit 43-3011-13 43-3011-13
43-3011-04 43-3011-04 Two Circuits 43-3011-04
ILMV330117 REV C 43-3011-05 Three or Four Circuits 43-3011-05
M8 PRESSURE SWITCH CONNECTION
75.4
6.5
120.42
120.42
150.79
1.00
0.51
VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT
5.35
M8 3 PIN FEMALE CONNECTOR END VIEW
62
62
M8 PRESSURE SWITCH CONNECTION 24.29 24.29
4.74
43-3011-05
43-3011-05
75.4
6.5
75.4
6.5
ILMV330117 REV C
PIN 1 ILMV330117 REV C
PIN 3 PIN 4 (NO CONNECT)
150.79
150.79
VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT
2.44
0.26
FIXTURE TRANSMITTER WIRING OPTIONS
0.96
CONNECTOR PIN NO. 1 NORMALLY OPEN 3 COMMON
FUNCTION NORMALLY OPEN*
2.97
5.94
*SWITCH CLOSED = PRESSURE GOOD
FIXTURE TRANSMITTER UNIT MODEL NO. 33-0111-03
MASTER CONTROL UNIT
Simple Guardian TM Convenience Package Easy 2 fixture setup monitoring 1 circuit per fixture!
MACHINE TOOL RECEIVER
Master Control Unit 1 Machine Tool Receiver 2 Fixture Transmitter Units
2 Pressure Switches and Cables All Necessary Wiring & Hardware
The Simple Guardian installs with only four wires (two power wires and a pair of output wires to M-code, door closed or other input confirmation wires). It is a quick and clean installation needing no modifications to the machine tool control. Leave the M-Code “call” check instructions out of your part program for non-monitored fixtures.
FIXTURE TRANSMITTERS
PRESSURE SWITCHES (WIRES NOT SHOWN)
ORDER MODEL NO. 33-0111-10
Simple Configuration Kit Machine Kit 1 Master Control Unit 1 Machine Tool Receiver All Necessary Wiring & Hardware ORDER MODEL NO. 33-0101-10 Single Circuit Transmitter Kit 1 Fixture Transmitter Unit
Simple Components Only Master Control Unit ORDER MODEL NO. 33-0110-14
Machine Tool Receiver
ORDER MODEL NO. 33-0111-02
Fixture Transmitter Units One Circuit
ORDER MODEL NO. 33-0111-03 Two Circuits ORDER MODEL NO. 33-0111-04 Three or Four Circuits ORDER MODEL NO. 33-0111-05
1 Pressure Switch and Cable ORDER MODEL NO. 33-0101-03
Dual Circuit Transmitter Kit
1 Two Circuit Fixture Transmitter Unit 2 Pressure Switches and Cables ORDER MODEL NO. 33-0101-04
QUESTIONS? Call: 800-992-0236 email: customersupport@vektek.com
Quad Circuit Transmitter Kit
1 Four Circuit Fixture Transmitter Unit (Use only 3 circuits if applicable) 4 Pressure Switches and Cables ORDER MODEL NO. 33-0101-05
www.vektek.com
Wiring
(SEE TABLE)
(SEE TABLE)
(SEE TABLE)
(SEE TABLE)
M12 5 PIN FEMALE CONNECTOR / M12 5 PIN FEMALE CONNECTOR MODEL NO. 27-7422-05 AND 27-9422-01
M12 8 PIN FEMALE CONNECTOR MODEL NO. 27-6424-04
CABLES
M12 5 PIN FEMALE CONNECTOR / M12 5 PIN FEMALE CONNECTOR MODEL NO. 27-7422-05 AND 27-9422-01
DESCRIPTION M12 8 PIN CABLE M12 8 PIN FEMALE CONNECTOR MODEL NO. 27-6424-04
MODEL NO. 27-6424-04 MODEL NO. 27-6424-04 27-9422-01 27-7422-03 27-7424-02 27-9422-01 27-7424-01 27-7422-03 27-7424-04 27-7424-02
END 2 OPEN END END 2 OPEN END
LENGTH (FT) 32.8 LENGTH (FT) 32.8 32.8 16.4
END 1 FEMALE STRAIGHT END 1 FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT FEMALE STRAIGHT
MCU MACHINE TOOL FEEDBACK* EXTENSTION CABLE - M12 5 PIN MASTER CONTROL UNIT TO MACHINE TOOL RECEIVER COMMUNICATION CABLE ** DESCRIPTION M12 8 PIN CABLE MCU MACHINE TOOL FEEDBACK* EXTENSTION CABLE - M12 5 PIN MASTER CONTROL UNIT TO MACHINE TOOL RECEIVER COMMUNICATION CABLE ** EXTENTION CABLE M8 3 PIN SHIELDED PRESSURE SWITCH TO FIXTURE TRANSMITTER EXTENTION CABLE M8 3 PIN SHIELDED PRESSURE SWITCH TO FIXTURE TRANSMITTER
CABLES
MALE STRAIGHT
MALE STRAIGHT
MALE STRAIGHT MALE STRAIGHT MALE STRAIGHT MALE STRAIGHT MALE STRAIGHT MALE STRAIGHT
3.5 32.8 2.2 16.4
1.2 3.5
FEMALE STRAIGHT
MALE STRAIGHT
2.2
27-7424-01
* Included with 33-0101-10 & 33-0111-10 can be purchase separately for replacement or additional hook up. ** 27-9422-01 is included with 33-0101-10 & 33-0111-10. Cables can be purchased separately for extension or replacement
FEMALE STRAIGHT
MALE STRAIGHT
1.2
27-7424-04
Pressure Switches
* Included with 33-0101-10 & 33-0111-10 can be purchase separately for replacement or additional hook up. ** 27-9422-01 is included with 33-0101-10 & 33-0111-10. Cables can be purchased separately for extension or replacement
GREEN LIGHT INDICATES PRESSURE IS GOOD
INCLUDES 19.7 IN M8 SHIELDED CABLE P/N 27-7424-01 FOR DIRECT CONNECTION TO FIXTURE TRANSMITTER INCLUDES 19.7 IN M8 SHIELDED CABLE P/N 27-7424-01 FOR DIRECT CONNECTION TO FIXTURE TRANSMITTER
VEKTEK Pressure Switch Setter/Checker VEKTEK Pressure Switch Setter/Checker GREEN LIGHT INDICATES PRESSURE IS GOOD
THIS DEVICE WITH A PRESSURE GAUGE ALLOWS YOU TO ACCURATELY IDENTIFY BOTH SET POINTS OF THE PRESSURE SWITCH - - RISING SET POINT AND FALLING FAULT POINT (THE CRITICAL PRESSURE). THIS DEVICE WITH A PRESSURE GAUGE ALLOWS YOU TO ACCURATELY IDENTIFY BOTH SET POINTS OF THE PRESSURE SWITCH - - RISING SET POINT AND FALLING FAULT POINT (THE CRITICAL PRESSURE).
SAE 4 MALE CONNECTION
PRESSURE SWITCHES
SAE 4 MALE CONNECTION
CONNECTORS 33-0110-15 Pressure Setter / Checker to assist setting mechanical pressure switches 70-7500-78 750 TO 5000 PSI PRESSURE SWITCH WITH SHIELDED19.7” CABLE (SHOWN) 70-7500-74 750 TO 5000 PSI PRESSURE SWITCH ONLY (M8 MALE CONNECTION *** ) 70-7500-78 750 TO 5000 PSI PRESSURE SWITCH WITH SHIELDED19.7” CABLE (SHOWN) 70-7500-74 750 TO 5000 PSI PRESSURE SWITCH ONLY (M8 MALE CONNECTION *** ) *** 70-7500-74 requires user provided 3 pin M8 shielded cable. 33-0110-15 Pressure Setter / Checker to assist setting mechanical pressure switches PRESSURE SWITCHES
27-5222-04 Guardian, M8 3 Pin Jumper, use with 33-0111-03,04,05 *** 70-7500-74 requires user provided 3 pin M8 shielded cable.
CONNECTORS
27-5222-04 Guardian, M8 3 Pin Jumper, use with 33-0111-03,04,05
Brazil - brasilsales@vektek.com +55-11-94012-0760 Canada - canadasales@vektek.com China - chinasales@vektek.com Dalian: +86-411-83779160 Shanghai: +86-21-58683679 Europe - internationalsales@vektek.com Israel - israelsales@vektek.com India - indiasales@vektek.com +91-40-27844279 Japan - japansales@vektek.com +81- 048-987-1371 Korea - koreasales@vektek.com Latin America - ventas@vektek.com Mexico - mexicosales@vektek.com
Vektek offers a complete line of PRECISION HYDRAULIC CLAMPING 1000 psi (7MPa) and 5000 psi Call today for more information!
VEKTEK LLC 1334 E 6th Avenue Emporia, KS 66801 www.vektek.com Factory Direct: 800-992-0236 913-365-1045