Things to Consider 1. Where are the M-Code terminals on your machine, and do you have any currently available ? 2. What are your best choice for communication terminals, are they available or will you need to tie into currently dedicated Door Closed, E-Stop or Feed Hold relays? 3. Is your machine positive or negative case ground (which is switched on/off) ? 4. What length of cables is going to be necessary to mount the Machine Tool Receiver to the Master Control Unit ? 5. For the best operator visibility to the status display, where will the Guardian Master Control Unit be mounted?
6. What location in the machine enclosure will you put the Guardian Machine Tool Receiver that has clear line-of-sight and will not be hit by the pallet or spindle ? 7. Where will you locate the Guardian Fixture Transmitters on your pallet that is visible to the focused field ? 8. What is the critical pressure lower limit at which you want to prevent machining ? 9. Will you need help from your Machine Tool Distributor’s service staff or does your staff have the ability to install the Guardian ?
4X 5
2X 8.5 4X 4.6
Fixture Transmitters
Operation
15
40
65.79
Guardian Simple Model 1. Wire the Simple Guardian to the control terminals that you want to use to prevent low pressure condition operation. 40 2X 8.5 4X 4.6 4X 5 40 2X 8.5 4X 4.6 4X 5 15
25.39
Fixture Transmitters 12.89
M8 PRESSURE SWITCH CONNECTION
Fixture Transmitters
43-3011-13
43-3011
120.42
15
65.79
65.79
62
2. Adjust the pressure switch to send a fault signal at critical pressure using the Pressure Setter/Checker when pressure is falling. 3. When pressure is detected, a go signal can be given to the door closed switch or other input choice. Or write the “call” into your program if using an “M” code confirmation as often as you want to monitor, this is typically done during tool changes with coolant off to reduce interference and costly demand on production time. 120.42 6.5 75.4 150.79 62 24.29 VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT M8 PRESSURE SWITCH CONNECTION 12.89 120.42 6.5 75.4 150.79 62 24.29 M8 PRESSURE SWITCH CONNECTION 12.89 25.39
24.29
25.39
43-3011-13 One Circuit 43-3011-13 43-3011-13
43-3011-04 43-3011-04 Two Circuits 43-3011-04
ILMV330117 REV C 43-3011-05 Three or Four Circuits 43-3011-05
75.4
6.5
150.79
VEKTEK P/N 43-3011-13 FIXTURE TRANSMITTER UNIT
Guardian Fixture Transmitters Select the appropriate Fixture Transmitter to monitor 1, 2, 3 or 4 circuits.
43-3011-05
43-3011-05
ILMV330117 REV C
ILMV330117 REV C