ITW Cullen Gable Restraint System 2024

Gable Restraint System

Class 1 Buildings / houses of single occupancy three storeys or less England & Wales and two storeys or less Scotland Timber Gable to Masonry fixing detail to cold roofs – continuous wallplate

Gable Panel

225mm maximum height between underside of wallplate and horizontal restraint strap

Insulation continued into gable panel

Breather membrane to face of gable panel

Roof insulation

Cullen FT Timber frame wall ties

Longitudinal truss bracing

Continuous wallplate 38mm min-75mm maximum depth

Level of truss wallplate

Solid blocking between truss and gable panel at horizontal restraint strap positions Gable panel to wallplate fixing - Paslode 3.1mm dia x min 75mm long smooth shank nails at maximum 175mm centres Vertical holding down strap plugged and screwed to blockwork

Mortar bed

Cullen RST-3 restraint straps at maximum 1200mm centre fixed to longitudinal truss bracing /

Cullen Gable Restraint Bracket (GRB) at maximum 1200mm centres

additional longitudinal bracing with 8 no. 4 x 25mm steel screws fixed to gable panel stud with 3 no. 3.4 x 35 mm square twist nails

Cavity insulation shown for indicative purposes only - thermal bridging and SAP calculations are plot specific Cavity trays and firestops to be detailed by building designer

at maximum 1.8m centres, Cullen VRS-900-100 strap

Gable Panel (without gable ladder)

Cullen PFS restraint straps fixed to solid timber noggins between trusses at maximum 2000mm centres with 3.4 x 35mm square twist nails, 8 no. to noggins and 4 no. to gable panel (2 no. top face & 2 no. cavity face)

Cullen RST-3 restraint straps at maximum 1200mm centres fixed to additional longitudinal bracing with 8 no. 4 x 25mm steel screws fixed to gable panel stud with 3 no. 3.4 x 35mm square twist nails

Gable Panel (with or without gable ladder)

Truss profile

Bottom rail of gable panel

Continuous wallplate 38mm min-75mm maximum depth

1200mm max

Mortar bed

1200mm max

1200mm max

1200mm max

Cullen Gable Restraint Bracket (GRB) at maximum 1200mm centres

Cullen VRS-900-100 fixed to top of bottom rail with 4 no. 3.4 x 35mm square twist nails

1800mm maximum

Vertical restraint strap plugged and screwed to blockwork at maximum 1.8m centres - Cullen VRS-900-100 installed to top of gable panel bottom rail

The latest version of the technical guide will always be the digital format on our website.

Technical support: 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk 4

Made with FlippingBook interactive PDF creator