Amtech ATV Cartridge Collector User Manual

Trouble Shooting Guide

Symptom

Possible Cause

Remedy

Blower does not start.

a. Open electrical supply circuit. b. Blower motor not wired for available voltage. a. Incorrect overload protection installed. b. Loose or incorrect termination of motor wiring. c. Incorrectly sized wire for motor load. a. Filter cartridges not properly installed. b. Damaged filter cartridge. c. Damaged filter cap(s). d. Worn filter cap. e. Loose filter clamping “T” Handle.

a. Trace circuit back from correct interruption. b. Rewire motor within motor box for proper voltage per motor data label. a. Replace overload protection with correctly sized components. b. Check all terminations of motor wiring.

Blower motor starts but does not continue operating.

c. Rewire motor circuit with proper wire size.

Dust Discharge from Collector outlet.

a. Reinstall filters.

b. Replace damaged filters. c. Replace damaged filter cap(s). d. Replace all filter caps. e. Tighten loose “T” Handle.

Insufficient Air Flow

a. Blower rotating backwards.

a. Check blower rotation. Blower should be rotating clockwise when viewed looking down over the motor. Refer to page 5 under Electrical for changing rotation direction. b. Check that all access panels, doors, dust drawers, drum lids and flex hose connections are tight. c. Check exhaust area for blockage and eliminate all material that causes restrictions. d. Remove and replace filter cartridges. e. Increase available air volume. f. Increase air pressure to Maximum of 100 PSI. g. Eliminate source of contamination and purge compressed air line. h. Confirm input power to timer board or controller. Refer to pulse control manual for further information. i. The “on - time” and “off - time” must be set to optimize filter pressure differential equilibrium. Refer to page 10 of this manual and to the timer board controller manual for additional detail.

b. Collector not sealed properly.

c. Blower exhaust area blocked.

d. Filter cartridges need to be replaced. e. Compressed air volume inadequate. f. Compressed air pressure inadequate. g. Compressed air contaminated with oil or water. h. Pulse cleaning not working.

i. Pulse cleaning not set up as required.

Clean, repair or replace valves. Refer to page 13.