Industrial Grey PVC-U Pipe And Fittings Water Analysi
Process Optical Dissolved Oxygen Sensor
Process Optical Dissolved Oxygen Sensor Type 2610
Features Type 2610 Optical DO measurement with no flow requirements No membranes or filling solutions Flexible communications, 4-20 mA and Modbus (RS485) Measurement Range: 0-20mg/L, 0-200% Saturation Applications Environmental Water Discharge Monitoring Drinking Water Reservoir Monitoring Municipal and Industrial Wastewater Treatment Aquatic Life Support
Overview: Process Optical Dissolved Oxygen Sensor
The Signet 2610 RDO® Pro is a rugged, reliable sensor designed to deliver accurate dissolved oxygen (DO) data across a wide measuring range while reducing maintenance costs. It features the latest optical technology for DO measurement and eliminates the replacement of membrane and reference solutions.
The Signet 2610 optical sensor cap is calibrated at the factory and requires no field calibration. The optical measurement technology resists abra- sion and bleaching allowing for a long life in many harsh applications. The DO sensor has a built in Modbus RS485 and 4 to 20 mA current loop outputs for ease of interface to existing control systems. Additional features include a 10 m (32.8 ft) cable with stripped and tinned ends as well as a titanium thermistor for improved compatibility in salt water applications.
Order Guide: Optical Dissolved Oxygen Sensor (4-20mA Output) This version provides a 4-20mA output for connection to a PLC
Optical Dissolved Oxygen Sensor
CODE
REF #
Blind 4-20mA output
3-2610-31 159 001 753
Order Guide: Optical Dissolved Oxygen Sensor (With Transmitter Display) This version provides a S3L output for connection to a 9900 Transmitter, please select either a field or panel mount option.
Optical Dissolved Oxygen Sensor
CODE
REF #
S3L output (use with Transmitter 9900
3-2610-41 159 001 754
Field Mount
CODE
REF #
Field Mount Transmitter Type 9900
3-9900-1 159 001 696
Mounting Kit (Required)
3-8050
159 000 184
Panel Mount
CODE
REF #
Panel Mount Transmitter Type 9900
3-9900-1P 159 001 695
1300 PIPING (1300 747 464)
V 4.3
PAAS Source Book 183
Made with FlippingBook - Online magazine maker