Engaging Torque Detection This setting is only possible when the screw engaging provides significantly higher torque than the previous free run. This function detects initial thread engagement. Engaging torque is often used in applications that require free running the driver before fastening. Once thread engagement is detected, the standard fastening parameters will complete the fastening procedure.

Parameter

Description

Range

Engaging Torque is calculated as a percentage of target torque. The engaging torque function is completed when this set percentage of target torque is met.

0-50.00% of target torque

Torque (%)

Speed (rpm)

Driver rotation speed before engaging Torque (%) is met.

Tool rpm range

Angle limit (degree) Time limit (0.1s)

Angle value for upper angle limit. This is an optional parameter. If value is ‘0’ the parameter is off. Time limit for engaging torque. This is an optional parameter. If value is ‘0’ the parameter is off.

0-10,000 degrees

0-10 seconds (0.1 second increments)

Angle clear after engaging

Off: Angle is counted for the entire fastening procedure. On: Angle count restarts when Torque (%) is reached.

Off/On

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com