ECT Plus Series Manual

Stage 2 - Prevailing torque Prevailing torque begins with the start prevailing angle and ends with the end prevailing angle. It is controlled by the prevailing target torque, start prevailing angle, end prevailing angle, min prevail torque limit, and max prevailing torque limit. controlled by the prevailing target torque, start prevailing angle, end prevailing angle, min prevailing

Stage 3 - Final rundown with standard fastening The final rundown begins when the end prevailing angle is reached and ends when the gradient seating point is reached. Standard fastening parameters control the final rundown. Stage 4 - Seating torque Seating point begins when gradient seating point is reached. Seating torque is controlled by gradient seating point, seating min torque limit, and seating max torque limit. The clamp torque immediately after the seating torque is applied. seating point, seating min torque limit, and seating max torque limit. The clamp torque step begins step begins Final rundown with standard fastening parameters control the final rundown.

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292