ECT Plus Series Manual

Fastening errors

Code Error message

Description

How to reset

300

Run time limit (Forward)

Over time limit on A260

Resetting A260 value

301

Run time limit (Reverse)

Over time limit on A261

Resetting A261 value

302

Model setting error

Failure in Model programming

Resetting Model

303

Model cancel

The Model process is canceled

Motor stall by loosening failure

Motor stall by loosening failure within time limit on A262

304

Resetting A262 value

309

Bit socket tray

Bit socket tray application error

310

Time over in screw counting Over the time limit of screw counting on A243

Resetting A243 value

When the work-piece moves out of the working area without complete number of fastening

311

Screw missing

Target torque reached before the Min angle

330

Min Angle error

Target torque reached over the Max angle

331

Target angle setting error

Resetting target angle

Target torque reached over the Max angle

332

Angle over

Resetting max angle

Operation stops before complete cycle of torque up by releasing lever trigger

333

No torque complete

Engaging torque detection fail

The engaging torque is not detected in time or angle limit

334

Check min, max torque range

335

Converted torque error

Converted torque is out of torque limit (%)

[AC/TM] Torque reached to the high limit of torque capacity

336

Over torque error

Resetting max torque

337

Torque up at free speed

Torque up occur at Free speed

Resetting thread tap max torque

338

Thread tap max torque error Over max torque at Thread tap

Thread tap min & max range error

339

Thread tap setting min, max torque range invalid

400

Ethernet port fail

Ethernet device IC initializing fail

Ethernet communication error related with socket

401

Ethernet socket error

500

Over temperature

Overtemperature over 70°C

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com