ECT-Series Manual

Soft Start

Unit

Range 0 ~ 300

Initial

msec

0

Description

Speed reach to the target in the setting time, Preset complement to acceleration controller parameter

Seating Point Torque %

Unit

Range 10 ~ 95

Initial

%

50

Description

In TC/AM: % of Target torque Auto speed slow down to ramp-up speed for torque control In AC/TM: to be set with same torque value as Snug torque, in % of Max torque

Torque Rising Time

Unit

Range

Initial

msec

50 ~ 200

50

Description

Time setting from seating point to the target

Ramp-up Speed

Unit rpm

Range

Initial Auto

Tool range

Description

Speed after seating to the end of tightening

Torque Compensation

Unit

Range

Initial

%

80 ~ 120

100

Description

Individual torque tuning on each preset, saved in the controller The torque output can be adjusted in the selected preset ONLY, it does not influence other presets. For details, please refer to page 55