Soft Start
Unit
Range 0 ~ 300
Initial
msec
0
Description
Speed reach to the target in the setting time, Preset complement to acceleration controller parameter
Seating Point Torque %
Unit
Range 10 ~ 95
Initial
%
50
Description
In TC/AM: % of Target torque Auto speed slow down to ramp-up speed for torque control In AC/TM: to be set with same torque value as Snug torque, in % of Max torque
Torque Rising Time
Unit
Range
Initial
msec
50 ~ 200
50
Description
Time setting from seating point to the target
Ramp-up Speed
Unit rpm
Range
Initial Auto
Tool range
Description
Speed after seating to the end of tightening
Torque Compensation
Unit
Range
Initial
%
80 ~ 120
100
Description
Individual torque tuning on each preset, saved in the controller The torque output can be adjusted in the selected preset ONLY, it does not influence other presets. For details, please refer to page 55