Engaging Torque Detection This setting is only possible when the screw engaging provides significantly higher torque than the previous free run.
Speed
Unit rpm
Range
Initial
Tool range
0
Description
Tool rotation speed
Torque (%)
Unit
Range 0 ~ 50
Initial
%
0
Description
Engaging torque setting by percentage of target torque – detection will be active from this value
Angle Limit (turn)
Unit
Range 0 ~ 20
Initial
0.1 turn
0
Description
Max engaging rotation in rev
Time Limit (sec)
Unit sec
Range 0 ~ 10
Initial
0
Description
Max engaging time lap
Angle Start from Engaging
Unit
Range
Initial
YES - NO
NO
Description
If select, the monitoring angle count is reset and start again from engaging torque detection point.