ECT-Series Manual

Engaging Torque Detection This setting is only possible when the screw engaging provides significantly higher torque than the previous free run.

Speed

Unit rpm

Range

Initial

Tool range

0

Description

Tool rotation speed

Torque (%)

Unit

Range 0 ~ 50

Initial

%

0

Description

Engaging torque setting by percentage of target torque – detection will be active from this value

Angle Limit (turn)

Unit

Range 0 ~ 20

Initial

0.1 turn

0

Description

Max engaging rotation in rev

Time Limit (sec)

Unit sec

Range 0 ~ 10

Initial

0

Description

Max engaging time lap

Angle Start from Engaging

Unit

Range

Initial

YES - NO

NO

Description

If select, the monitoring angle count is reset and start again from engaging torque detection point.