ECT-Series Manual

Fastening setting : The fastening with counting number follows all settings and features in Screw Count menu except the number of screw.

The spindle can be locked automatically in all steps except Fastening step, by selecting Enable on the menu Controller ‘Auto lock’ (model).

Input/Output setting: IO port used in models should be unassigned (None) in IO settings Inputs port 9 to 15 are unassigned and dedicated to models

Command details

Command Description

Data 1

Data 2

0: No output  NG 1: Active High 2: Active Low 3: High status 4: Low status 0: No Output  NG 1: On 2: Off 3: On for 0.5s and Off 4: On for 1.0s and Off

Input # select from 1 - 8

Input

Mapping digital Input

Output # select from 1 - 8

Output

Mapping digital Output

Preset # from 1 – 13

Fastening

Start fastening

Count number from 1 - 250

14 : MA* 15 : MB*

Delay

Delay time

-

1 to 250 (unit: 0.1s) 0.1 - 25 sec.

Barcode step data: ‘1 to 30’ registered barcode(step) ‘0’ any barcode scan

Bar code

Require bar code scan

None

* To select preset 14 and 15, please program preset 14 and 15 in a one step multi-sequence.