ECT-Series Manual

Error display reset time

Unit sec

Range 0 ~ 10

Initial

1,0

Description

Error display and reset after the below set time Value 0: manual reset with RESET button

Fastening OK signal time

Unit

Range 0 ~ 500

Initial

ms

200

Description

Signal output time setting longer than 150ms which is factory setting. Shorter time than factory setting doesn’t work.

Screw type

Unit

Range

Initial

CW - CCW

CW

Description

Set tightening rotation direction for each preset

Judged fasten minimum turn Unit

Range

Initial

turn

0 ~ 5

0

Description

Turns out of judgement

Fastening stop error

Unit

Range

Initial OFF

OFF- ON

Description

NO: does not create any NG when the tool stops without fully tightening by torque up.

Alarm sound control

Unit

Range

Initial

OFF- ON

ON

Description

Activation of noise alarm – stops when reset (timer or manual)

Torque calibration

Unit

Range

Initial

%

90 ~ 110

100

Description

It is the master calibration for whole range of tool. Saved in the tool memory and effective on another controller. The F/R switch should be at Reverse position before writing the new value. For details, please refer to page 55.

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com

28