Error display reset time
Unit sec
Range 0 ~ 10
Initial
1,0
Description
Error display and reset after the below set time Value 0: manual reset with RESET button
Fastening OK signal time
Unit
Range 0 ~ 500
Initial
ms
200
Description
Signal output time setting longer than 150ms which is factory setting. Shorter time than factory setting doesn’t work.
Screw type
Unit
Range
Initial
CW - CCW
CW
Description
Set tightening rotation direction for each preset
Judged fasten minimum turn Unit
Range
Initial
turn
0 ~ 5
0
Description
Turns out of judgement
Fastening stop error
Unit
Range
Initial OFF
OFF- ON
Description
NO: does not create any NG when the tool stops without fully tightening by torque up.
Alarm sound control
Unit
Range
Initial
OFF- ON
ON
Description
Activation of noise alarm – stops when reset (timer or manual)
Torque calibration
Unit
Range
Initial
%
90 ~ 110
100
Description
It is the master calibration for whole range of tool. Saved in the tool memory and effective on another controller. The F/R switch should be at Reverse position before writing the new value. For details, please refer to page 55.
SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com
28