ECT-Series Manual

Preset # display when power on Unit

Range 1 ~ 15

Initial

1

Description

Choice of initial preset selection on display when power on.

RS232 select

Unit

Range

Initial

MODBUS - Barcode

MODBUS

Description

RS232 Port use: for data report or barcode reader

Please ensure that baud rate is set to correct value

Comport baud rate setting

Unit

Range

Initial

bauds

9600 ~ 230400

115200

Description

RS232 communication speed To be set as computer com port:115200 bauds for MountzCom PC or barcode reader setting : 9600 bauds

Auto data output

Unit

Range

Initial OFF

OFF - ON

Description

Fastening data output automatically on every events as like run, For/Rev change, torque up, preset change, etc. Monitoring data come out through RS232 or Ethernet without data request command

Auto data output port

Unit

Range

Initial

RS232 - Ethernet

RS232

Description

Data output port selection for automatic report Auto data should be also set on

Protocol

Unit

Range

Initial

MODBUS - OPEN

MODBUS

Description

MODBUS OPENL Refer to Protocol manual