25P I/O Schematic The digital I/O provide the free assignment feature for 8 Inputs and 8 Outputs. Factory setting of I/O assignments are as following.
To validate changing I/O, turn the power OFF and ON again
I/O connections
Factory settings
Pin No
Factory setting
Description
1
IN 1
Preset select 1
2
IN 2
Preset select 2
3
IN 3
Preset select 3
4
IN 4
Start
5
IN 5
Forward / Reverse
6
IN 6
Driver Lock
7
IN 7
Multi Multi-sequence
8
IN 8
Alarm Reset
Non assignable only
IN 9
9
Model
10
OUT 1
Torque UP
11
OUT 2
Fastening OK
12
OUT 3
Ready
13
OUT 4
Motor RUN
14
OUT 5
Alarm
15
OUT 6
Status F/L
16
OUT 7
Count complete
17
OUT 8
Alarm 1
Non assignable only Model Non assignable only Model Non assignable only Model
IN 10
18
IN 11
19
IN 12
20
21
Out COM
22
In COM
Non assignable only Model Non assignable only Model Non assignable only Model
IN 13
23
IN 14
24
IN 15
25
SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com