ECT-Series Manual

25P I/O Schematic The digital I/O provide the free assignment feature for 8 Inputs and 8 Outputs. Factory setting of I/O assignments are as following.

To validate changing I/O, turn the power OFF and ON again

I/O connections

Factory settings

Pin No

Factory setting

Description

1

IN 1

Preset select 1

2

IN 2

Preset select 2

3

IN 3

Preset select 3

4

IN 4

Start

5

IN 5

Forward / Reverse

6

IN 6

Driver Lock

7

IN 7

Multi Multi-sequence

8

IN 8

Alarm Reset

Non assignable only

IN 9

9

Model

10

OUT 1

Torque UP

11

OUT 2

Fastening OK

12

OUT 3

Ready

13

OUT 4

Motor RUN

14

OUT 5

Alarm

15

OUT 6

Status F/L

16

OUT 7

Count complete

17

OUT 8

Alarm 1

Non assignable only Model Non assignable only Model Non assignable only Model

IN 10

18

IN 11

19

IN 12

20

21

Out COM

22

In COM

Non assignable only Model Non assignable only Model Non assignable only Model

IN 13

23

IN 14

24

IN 15

25

SILICON VALLEY HEADQUARTERS 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292 1080 North 11th Street, San Jose, CA 95112 | Phone: (408) 292-2214 | Fax: (408) 292-2733 | mountztorque.com