Leopardo Proposed Technical Center Outline Specifications Page 18 of 25 12/13/2012
13. CONVEYING SYSTEMS (if used) 13.1. Provide (1) 2,500# hydraulic 2-stop elevator equal to Thyssen Krupp Model AMEE20 with standard laminate panel finished cab, baked enamel finish on hoist way jambs, baked enamel finish on single doors (1 per floor) and meets all safety and ADA requirements.
14. MECHANICAL
14.1. Plumbing a) The plumbing work of the entire building is to conform to the following:
i. Provide all required building plumbing work and process related plumbing work as identified in the Technical Criteria Matrix. ii. Standard plumbing fixtures to be similar or equivalent to those as manufactured by Koehler, American Standard or Elkay. Pressure assisted toilets. iii. Provide line voltage operated touchless faucets/valves/urinals and hand cleaners in all bathrooms. iv. Provide two (2) polished stainless steel Bradley® wash fountains, 54 in wide, semi circular, foot bar operation type v. Floor drains to be similar to equivalent to those as manufactured by Wade. Water heater(s) to be similar or equivalent to those as manufactured by Lochinvar or A.O. Smith. vi. Water cooler(s) to be similar to equivalent to those manufactured by Oasis, Coroley, Halsey Taylor. vii. Showers in locker rooms shall be full height, one piece, fiberglass units with integral floors. viii. All services are to be made complete and functional with final connections having been made to existing utilities. Work is to be completed in a neat, workmanlike manner. ix. Provide miscellaneous piping and other items of work as might be required to complete the plumbing system. b) Domestic Water i. Provide a complete domestic and process plumbing system including restrooms, coffee bars, lunchroom, and other areas as identified in the Technical Criteria Matrix. ii. Provide exterior frost proof hose bibbs and domestic water piping for hose bibbs (minimum of one per wall direction; N, S, E, W). iii. Domestic hot water shall be generated from a gas fired water heater. A recirculation pump shall maintain a hot water temperature of 120 degrees F. The domestic hot and cold water shall be distributed through Type L copper tubing with 95-5 solder fittings.
iv. Provide water supply piping system for irrigation. v. Provide (1) hose bibb in each dynamometer test cell. c) Sanitary
i. Provide a complete sanitary system to service all toilet fixtures, sinks, urinals, water coolers, floor drains, oil / water interceptors and other required plumbing devices. ii. Sanitary sewer piping system (inside and outside of the building) shall be PVC or cast iron piping at the engineer’s discretion and connected to the municipality’s sanitary lead. iii. Provide storm piping including roof conductors and overflow protection. iv. Provide cast trench drain and grating in each truck well and at exterior overhead grade doors, all drains tied to an oil / water separation system.
v. Provide one (1) floor drain in each of four Janitor’s Closets. vi. Provide (5) additional floor drains, location to be determined.
Return to Table of Contents