Smart Touch 3 Oven Start-Up & Commissioning 24 Access.

Zone 1 Combustion Fan Amps

Zone 2 Combustion Fan Amps

Phase A _________ Phase B _________ Phase C _________

Phase A _________ Phase B _________ Phase C _________

Measure amps on the wires leaving MR1 Contactor while the combustion fan is running correct rotation.

Zone 1 Exhaust Fan Amps

Zone 2 Exhaust Fan Amps

Phase A _________ Phase B _________ Phase C _________

Phase A _________ Phase B _________ Phase C _________

Measure amps on the wires leaving MR2 Contactor or exhaust VFD while the exhaust fan is running correct rotation.

Zone 1 Recirculation Fan 1 Amps

Zone 1 Recirculation Fan 2 Amps

Phase A _________ Phase B _________ Phase C _________

Phase A _________ Phase B _________ Phase C _________

Measure amps on the wires leaving MR3 & 4 Contactor while the Reciculation fan is running correct rotation.