Professional chiller series BlueCool P-Series
BlueCool P-Series Twin chiller
Type
P60 T
P72 T
P84 T
P96 T
P120 T
Cooling capacity* (BTU / h)
60,000
72,000
84,000
96,000
120,000
Cooling capacity* (kW)
17.6
21.1
24.6
28.1
35.2
Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
14
16
19
25
–
Current draw running** (A) for 400 V 3-phase
5.8
7.1
8.1
10
12
Current draw running** (A) for 208 V 3-phase
10
12
14
17
33
Current draw running FLA**** (A) for 230 V 1-phase Current draw running FLA**** (A) for 400 V 3-phase Current draw running FLA**** (A) for 208 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 208 V 3-phase
30
35
46
47
–
10
11
14
20
22
20
22
27
37
50
61
76
100
114
–
32
40
46
50
59
70
83
95
98
139
Min. chilled water flow (l / min.)
50
60
66
76
100
Min. seawater flow (l / min.)
38
46
56
64
80
Recommended seawater pump+
WB1500 WB2000
WB2500G WB3000G
WB2500G WB3000G
WB2500G WB3000G
WB3000G WB3500
Dimensions (L x W x H) (mm)
560 x 660 x 600
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 675
Dimensions (L x W x H) (inch)
22 x 26 x 23.6
22 x 27.3 x 24.6
22 x 27.3 x 24.6
22 x 26.9 x 26.6
22 x 31.1 x 26.6
Dimensions (L x W x H) (mm) tropical
560 x 660 x 625
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 725
Dimensions (L x W x H) (inch) tropical
22 x 26 x 24.6
22 x 27.3 x 24.6
22 x 27.3 x 24.6
22 x 26.9 x 26.6
22 x 31.1 x 28.5
Weight (kg)
90
95
100
130
160
Available options 230 V / 1-phase
–
n
n
n
n
208 V / 3-phase
n
n
n
n
n
Reverse Cycle Heating
n
n
n
n
n
Cool Only version
–
–
–
–
–
Tropicalized version
n
n
n
n
n
Soft Start 400 V/230 V/208 V
n / n / –
n / n / –
n / n / –
n / – / –
n / – / –
Upgrade box/MCA Box
n
n
n
n
n
Silent Block
n
n
n
n
n
The BlueCool P-Series: Wide product range for medium and large size boats Scroll compressors for heavy duty applications Low starting surge through staged compressor starts 208 V, 230 V and 400 V systems available Many customization options with different electronics, tropical versions, vibration damping and many other features Fully independent refrigerant circuits in multiple compressor units provide high system availability Power output continuously adapted to cooling demand Very robust stainless steel design for heavy duty use
General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature. ** Amperage values for core unit at nominal conditions at 50 Hz. **** FLA (Full Load Amperage) is the current draw at maximum conditions. + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow. ++ B lueCool P-Series systems are tested and approved by Webasto for 50/60 Hz operation. n Standard n Option – Not available
13
Made with FlippingBook Online newsletter