Webasto BlueCool self-contained units BlueCool S-series 115 V
Technical data
BlueCool S-Series 115 V
Type
S6-R-115V- REV-R410a
S8-R-115V- REV-R410a
S10-R-115V- REV-R410a
S13-R-115V- REV-R410a
S16-R-115V- REV-R410a
Order numbers
2510139
2510140
2510141
2510142
2510143
Cooling capacity (BTU / h) *1
6,000
8,000
10,000
13,000
16,000
Cooling capacity (kW) *1
1.8
2.4
2.9
3.8
4.7
Heating via reverse cycle integrated
yes
yes
yes
yes
yes
Voltage (V)
115
115
115
115
115
Frequency (Hz)
60
60
60
60
60
Current consumption, operation [A] 60Hz *2
3.6 – 5.5
4.5 – 6.1
5.6 –7.9
7.6 – 11
8.0 – 15.7
Max. starting current intake, current peak [A] 60 Hz
39
54
55
70
89
Starting current intake RMS40 [A] 60 Hz *3
25
35
36
47
59
Starting current intake RMS300 [A] 60 Hz *4
19
20
21
30
35
Current consumption with blocked rotor LRA [A]
27
34
37
57
70
275 (162)
275 (162)
350 (206)
430 (253)
650 (382)
Fan output, free-blowing [m³/h] (cfm)
Supply air grille [cm 2 ]
150
235
235
250
390
Air inlet grille [cm 2 ]
325
490
490
550
800
Mnimum thickness insulation air duct [mm] (inch)
4
4
4
4
4
Recommended line fuse protection [A]
16
16
16
16
25 * 5
100 (4)
100 (4)
100 (4)
125 (5)
125 (5)
Fan connection [mm] (inch)
ø Sea water connection [mm] (inch)
19, 3/4”
19, 3/4”
19, 3/4”
19, 3/4”
19, 3/4”
Min. seawater flow rate {l/min] 60 Hz
6
8
10
12
14
Recommended seawater pump 60 Hz *6
WB250
WB350
WB350 WB350/WB500G WB500/WB500G
max. permissible ambient temperature [ ° C]
+40
+40
+40
+40
+40
Dimensions L x W x H (mm) Dimensions L x W x H (inch)
400 x 320 x 305 15.7 x 12.6 x 12.0
400 x 320 x 310 15.7 x 12.6 x 12.2
475 x 330 x 310 18.7 x 12.2 x 12.2
500 x 330x 325 19.7 x 13.8 x 12.6
540 x 350 x 380 21.3 x 13.8 x 15
Refrigerant quantity R410a [g]
440
260
240
420
400
Minimum sea water temperature in heatling mode
6
6
6
6
6
Maximum sea water temperature in cooling mode
35
35
35
35
35
Weight [kg]
18
18
20
25
28
* 1 BTU/h and electrical data are based on 7 °C evaporation temperature and 38 °C condensation temperature * 2 Current consumption of self-contained air-conditioning unit is dependent on compressor output. Maximum values under tropical conditions. * 3 Effective value of current consumption (RMS) for the self-contained air-conditioning unit for the first 40 ms * 4 Effective value of current consumption (RMS) for the self-contained air-conditioning unit for the first 300 ms * 5 Compressor only * 6 Only a recommendation. The pump size must be adjusted to the application so that the minimum flow rate is ensured.
38
Made with FlippingBook Online newsletter