Webasto BlueCool self-contained units BlueCool S-series 230 V
Technical data
BlueCool S-Series 230 V
Type
S6
S8
S10
S13
S16
S20
S27
Order numbers
WBCL120000A WBCL120001D WBCL120002D WBCL120003D WBCL120004D WBCL120005D WBCL120006D
Cooling capacity* (BTU / h)
6,000
8,000
10,000
13,000
16,000
20,000
27,000
Cooling capacity* (kW)
1.8
2.4
2.9
3.8
4.7
5.9
7.9
Heating via reverse cycle integrated
yes
yes
yes
yes
yes
yes
yes
Voltage (V)
230
230
230
230
230
230
230
Frequency (Hz)
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Current draw running** (A) 50 Hz
2 – 2.4
2.4 – 3.5
2.6 – 4.0
3.6 – 6.3
4.9 – 7.1
5.9 – 8.9
7.0 – 10.5
Current draw max. peak (A) 50 Hz
87
14
28
27
37
54
60
Current draw RMS40**** (A) 50 Hz
5
17
17
22
35
39
58
Current draw RMS300*** (A) 50 Hz
3
9
9
11
19
20
37
Current draw max. peak with Soft Start (A) 50 Hz Current draw RMS40**** with Soft Start (A) 50 Hz Current draw RMS300*** with Soft Start (A) 50 Hz
11
12
11
13
22
23
36
4
7
7
7
12
14
20
3
5
5
5
9
10
18
Locked Rotor Amperage LRA (A)
12
19
19
24
37
43
62
Max. circuit breaker (A)
16
16
16
16
16
16 20 (comp. only)
Air flow (free blowing) (m³/ h) Air flow (free blowing) (cfm) Seawater connection (mm) Seawater connection (inch)
275 162 19 3/4”
275 162 19 3/4”
400 235 19 3/4”
500 294 19 3/4”
625 368 19 3/4”
625 368 19 3/4”
2 x 550 2 x 324
19 3/4”
Min. seawater flow at 50 Hz (l/min.)
6
8
10
12
14
17
21
Min. seawater flow at 60 Hz (l/min.)
7,5
10
12
14
17
20
25
Recommended seawater pump +
WB250
WB350
WB350 WB350/WB500G WB500/WB500G WB500/WB500G WB1000WB1000G
Dimensions L x W x H (mm) Dimensions L x W x H (inch) Blower connection (mm) Blower connection (inch)
400 x 320 x 305 15.7 x 12.6 x 12.0
400 x 320 x 305 15.7 x 12.6 x 12.0
475 x 330 x 310 18.7 x 12.2 x 12.2
500 x 350 x 320 19.7 x 13.8 x 12.6
540 x 350 x 370 21.3 x 13.8 x 14.6
590 x 340 x 370 23.2 x 13.4 x 14.6
570 x 510 x 410 22.4 x 20.1 x 16.1
100 4
100 4
100 4
125 5
125 5
125 5
2 x 125 2 x 5
Weight (kg)
20
20
22
27
31
34
46
General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU/h are based on 7° C evaporating temperature and 38° C condensing temperature ** Amperage values for core unit depend on compressor load. Max values at tropical conditions at 230 V/50 Hz *** Starting amperage RMS (Root Mean Square) for core unit for first 300 ms **** Starting amperage RMS (Root Mean Square) for core unit for first 40 ms + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.