Configuration options BlueCool P-Series
Configure your chiller system in 6 main steps:
Product options for BlueCool P-Series The BlueCool P-Series is highly customizable to the demands of shipyards and national legislation. In addition to a wide range of cooling capacities, many options can be selected to customize the chiller to your needs. For further options, please contact the sales support team at Webasto.
Option 1: Voltage All P-Series chillers are available as 400 V / 3-phase version. On most models 208 V / 3-phase or 230 V / single phase is available as well.
Option 2: Cool only version For regions where heating is not required some units are available as cool only version.
Option 3: Tropical version For high sea water temperatures > 32 °C, a tropical chiller version with enlarged condensers shall be selected to avoid high pressure cut-outs. Option is highly recommended whenever the boat may travel in regions where sea water temperatures may be above 32 °C.
Option 4: Soft start In order to reduce the amperage draw at compressor start a soft start may be chosen as an option.
BlueCool Expert tool for service, configuration, application tuning, diagnosis and system setup comes as a standard free of charge Optional CAN-Bus for integration into boats central monitoring systems Unique Thermostatic Advance Function for power output continuously adapted to cooling demand Redesigned trays for easier mounting of silent blocks to reduce vibrations Electrical systems can be upgraded to customer needs with PRO box or fulfilling MCA requirements
Soft start devices are reducing the amperage peak at compressor start up to 53 % Soft start models are available for 400 V 3-phase as well as 230 V single phase The peak reduction allows to better size the power generator and it frees capacities for other electrical consumers Light flickering is reduced Circuit breakers and cables sizes do not have to be oversized The soft starts fit into the standard electri- cal box if no further electrical accessories are chosen
If the soft starts are selected during the chiller configuration process they come already installed and tested as part of the electronic box
9
Made with FlippingBook Online newsletter