Installation of Mechanically Attached System: •All field sheets incorporate 6” control lines for overlap and fastener placement. •Start at the low point of the roof and position a half-width (39'' or 991mm) roll of TPA Roof Membrane square with the roof edge. Avoid wrinkles. Reposition when necessary. •Mechanically attach underlying sheet at the lap to the struc- tural deck with fasteners and 2 3/8'' (60 mm) diameter barbed membrane plates spaced at 6'' (153 mm) on center (or as specified) down the entire lap with the disc centered 1-1/8'' (29 mm) from the sheet edge. •Overlap perimeter sheet at side lap: 4.5'' (114 mm) mini- mum. Overlap at end lap: 3” (76 mm) minimum. Overlap field sheet 6” (153 mm) minimum. •The minimum number of half- width rolls required at the peri meter is 2. Determine the perimeter width as described in Section 2.2 of Factory Mutual Loss Prevention Data Sheet 1-28. Consult your Tremco Representative for further information. •Install the required number of half-width perimeter rolls along the roof edges both parallel and perpendicular to the roll direction in the field of the roof. Overlap perimeter sheets in the corner areas with perimeter fastener rows installed through both membranes in both directions. Install a mini- mum 6 inch (150 mm) wide cover strip centered over the fastener rows. Installation of Ballasted System: •Mechanically attach or adhere the membrane in the perimeter areas, using the required number of half width rolls, as deter- mined. •Unless otherwise specified, minimum ballast coverage is 1000 lbs/SQ, using ASTM D 448-98, number 4, 3/4” to 1 1/2” (19mm to 28mm). Gravel ballast shall be smooth, water worn, with rounded edges and corners. •During installation of ballast, do not create piles on the roof deck. Membrane Seaming: •All surfaces must be clean and dry. •For heat welding, allow the hot air welder to warm up. Insert the nozzle tip of the hot air welder into seam area. Move nozzle at a steady speed along the seam area, immediately applying pressure behind the air nozzle with a Neoprene roller or weighted wheel to ensure positive contact of the heated TPA Roof Membrane lap. Minimum width of welded lap shall be 1.5” (38.1 mm) when using an automatic welder. Hand welds shall be a minimum 2”(51 mm) wide. •Field test heat welded laps to assure proper construction. Perform field test after lap area cools to ambient tempera- tures. Properly constructed laps will not separate at the lap interface when tested. Consult your Tremco representative for additional information. Perimeter/Projection Attachment: Provide mechanical attachment of roofing membrane at roof perimeter, walls, expansion joints, and all other projections. Follow the recom- mendations of Factory Mutual Loss Prevention Data Sheets 1- 28, 1-29, and 1-49. Precautions: Users must read container labels and Material Safety Data Sheets for health and safety precautions prior to use. Availability and Cost: Contact your local Tremco Roofing Representative for pricing and availability. For the name and number of your Representative, call the Roofing Division at 216/292-5000. Maintenance: Your local Tremco Roofing Representative can provide you with effective maintenance procedures which may vary, depending upon specific conditions. Periodic inspections, early repairs and preventative maintenance are all part of a sound roof program. The solar reflectance of this roofing product may decrease over time. Roofs should be properly examined at regular intervals and maintained or cleaned when necessary and appropriate to assure maximum reflectance.

Physical Performance Characteristics

TPA Roof Membrane

Property

Typical Value

Test Method

Thickness

0.045 in (1.14 mm) ASTM D 751-00 0.060 in (1.52 mm) 0.080 in (2.03 mm)

Tensile strength 300 lbf

ASTM D 751-00

(1330N)

Elongation

25% MD 25% XMD

ASTM D 751-00

@ fabric break

Tear strength

100 lbf (440N)

ASTM D 751-00

Dimensional stability 0.3%

ASTM D 1204-94

@ 176°F

@ 6 hrs.

Low temperature -40°F

ASTM D 2136-94

flexibility

(-40°C)

(1998)

Reflectivity

0.86 (initial)

ASTM C 1549-02

Thermal emittance 0.86 (initial)

ASTM C 1371-98

SRI-Solar Reflective 108 (initial)

ASTM E 1980-11

Index

84 (3 years)

Recycled content

25% Preconsumer

Guarantee/Warranty: Tremco, Inc. warrants TPA Roof Membrane to be free of defects and to meet published physical properties when tested according to ASTM and Tremco standards. Under this warranty, any product that is proved to be defective when applied in accordance with our written instructions, and in applications rec- ommended by Tremco as suitable for this product will be replaced with like product at no charge. THIS IS BUYERS SOLE AND EXCLU- SIVE REMEDY. All claims concerning product defects must be made in writing within twelve (12) months of shipment. The absence of such claims in writing during this period will constitute a waiver of all claims with respect to such product. This warranty shall be IN LIEU OF any other warranty, express or implied, including but not limit- ed to, any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Technical Services: Your local Tremco Representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications. The services of the Tremco Research Center, which has earned a unique reputation in weatherproofing technology, complement and extend the services of the Tremco Technical Service staff. Statement of Policy and Responsibility: Tremco takes responsibility for furnishing quality materials and for providing specifications and recommendations for their proper installation. As neither Tremco itself not its Representatives practice architec- ture or engineering, Tremco offers no opinion on, and expressly disclaims any responsibility for the soundness of any structure on which its products may be applied. If questions arise as to the soundness of a structure or its ability to support a planned installa- tion properly, the Owner should obtain the opinion of competent structural engineers before proceeding. Tremco accepts no liability for any structural failure or for resultant damages, and no Tremco Representative is authorized to vary this disclaimer. 3735 Green Road Beachwood, OH 44122 216-292-5000