TremSEAL ® Pro
Coverage Rates: 308’ of joint per gallon for a ¼’ x ¼” (6 mm x 6 mm) joint, which corresponds to approximately 25 linear feet per cartridge. Priming: TremSEAL Pro typically adheres to common construction substrates without primers. However, Tremco always recommends that a mock-up or field adhesion test be performed on the actual materials being used on the job to verify the need for a primer, proper cleaning and prep requirements. A description of the field adhesion test can be found in the appendix X1 of ASTM C1193, Standard Guide for Use of Joint Sealants.
APPLICATION: (continued)
Where required, use Geogard ® Primer on porous substrates and AlphaGuard M-Prime for metals or plastics.
Application: TremSEAL Pro is easy to apply with conventional caulking equipment. Ensure that the closed cell polyethylene backer rod is fitted properly for friction and that any necessary primers have been applied. Avoid three side joint adhesion with either backer rods or bond breaker tape to ensure a long lasting installation. Fill the joint completely with a proper width-to-depth ratio, and then tool to ensure intimate contact of sealant with joint substrates. The minimum width and depth of any sealant application should be ¼” x ¼” (6 mm x 6mm). The depth of sealant may be equal to width of joints less than ½” wide.
SKIN & OVERCOAT TIME:
2 hours with a tack-free time of 6 – 8 hours to significantly reduce dirt attraction.
Store in original, undamaged packaging in a clean, dry, protected location with temperatures between 40° to 100° F (5°-43° C). Excess sealant and smears adjacent to the joint interface can be carefully removed with mineral spirits before the sealant cures. Any utensils used for tooling can also be cleaned with mineral spirits.
CLEAN UP:
PRECAUTIONS:
Use with adequate ventilation.
Always utilize the accompanying SDS for information on Personal Protective Equipment (PPE) and Health Hazards.
TECHNICAL SERVICES:
Your local Tremco Representative, working with the Technical Service Staff, can help analyze conditions and needs to develop recommendations for special applications. The services of the Tremco Research Center, which has earned a unique reputation in weatherproofing technology, complement and extend the services of the Tremco Technical Service Staff. Your local Tremco Roofing Representative can provide you with effective maintenance procedures which may vary, depending upon specific conditions. Periodic inspections, early repairs and preventative maintenance are all part of a sound roof program.
MAINTENANCE: