Bid 1101

SECTION 07720

PART 1 GENERAL

1.1 SUMMARY

Provide and install freestanding KeeGuard® Roof Edge Protection System, including pipe railings, uprights, bases, counterweights, fittings and delivery to site.

RELATED SECTIONS

A.

Section 05500 - Metal Fabrications: Associated metal supports.

B. Section 07400 - Membrane Roofing: Coordination of roof edge protection installation.

1.2 REFERENCES

A. American National Standards Institute (ANSI) - A21.l Safety Requirements for Floor and Wall Openings, Railings and Toe Boards.

B. American National Standards Institute (ANSI) - A58.l Minimum Design Loads in Buildings and Other Structures.

C. American National Standards Institute (ANSI) - Al 17.1 Accessible and Usable Buildings and Facilities.

D. American Society of Testing and Materials (ASTM) A47 - Standard Specification for Ferrite Malleable Iron Castings.

E. American Society of Testing and Materials (ASTM) A53 - Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless.

F. American Society of Testing and Materials (ASTM) A153 - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware.

G. American Society of Testing and Materials (ASTM) A500 - Standard Specification for cold-formed welded and seamless carbon steel structural tubing.

H. Occupational Safety & Health Administration (OSHA): 1910.23 - Guarding Floor and Wall Openings and Holes.

05520-1